DATASHEET
ISL70419SEH, ISL73419SEH
Radiation Hardened 36V Quad Precision Low Power Operational Amplifiers with
Enhanced SET Performance
FN8653
Rev.3.00
Nov 21, 2019
The ISL70419SEH and ISL73419SEH contain four very high
Features
precision amplifiers featuring the perfect combination of low
• Electrically screened to DLA SMD# 5962-14226
noise vs power consumption. Low offset voltage, low I
BIAS
current, and low temperature drift make it the ideal choice for
applications requiring both high DC accuracy and AC
performance. The combination of high precision, low noise,
low power, and small footprint provides the user with
outstanding value and flexibility relative to similar competitive
parts.
• Low input offset voltage. . . . . . . . . . . . . . . . . . . ±110µV, Max.
• Superb offset temperature coefficient. . . . . . . 1µV/°C, Max.
• Input bias current . . . . . . . . . . . . . . . . . . . . . . . . . ±15nA, Max.
• Input bias current TC . . . . . . . . . . . . . . . . . . . . ±5pA/°C, Max.
• Low current consumption . . . . . . . . . . . . . . . . . . . . . . . 440µA
• Voltage noise . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8nV/Hz
• Wide supply range . . . . . . . . . . . . . . . . . . . . . . . . . .4.5V to 36V
• Operating temperature range. . . . . . . . . . . .-55°C to +125°C
Applications for these amplifiers include precision active
filters, medical and analytical instrumentation, precision
power supply controls, and industrial controls.
The ISL7x419SEH are offered in a 14 Ld hermetic ceramic
flatpack package. These devices are offered in an industry
standard pin configuration and operate across the extended
temperature range from -55°C to +125°C.
• ISL70419SEH radiation acceptance testing
- High dose rate (50-300rad(Si)/s): 300krad(Si)
- Low dose rate (10mrad(Si)/s): 50krad(Si)
Applications
• Precision instrumentation
• Spectral analysis equipment
• Active filter blocks
• ISL73419SEH radiation acceptance testing
- Low dose rate (10mrad(Si)/s): 50krad(Si)
• SEE hardness (see SEE report for details)
2
- SEL/SEB LET (V = ±18V): 86.4MeV•cm /mg
• Thermocouples and RTD reference buffers
• Data acquisition
TH
S
• Power supply control
Related Literature
For a full list of related documents, visit our website:
• ISL70419SEH, ISL73419SEH device pages
10
CH2 = V
- B
OUT
= ±15V
S
9
8
7
6
5
4
3
2
1
0
V
C
1
8.2nF
V
+
-
ISL70419SEH
+
OUTPUT
R
R
2
1
V
IN
1.84k
4.93k
3.3nF
C
2
V
-
-8
-6
-4
-2
0
2
4
SET EXTREME DEVIATION (V)
SALLEN-KEY LOW PASS FILTER (f = 10kHz)
C
2
FIGURE 1. TYPICAL APPLICATION
FIGURE 2. SET DEVIATION vs DURATION FOR LET = 60MeV•cm /mg
FN8653 Rev.3.00
Nov 21, 2019