IR
Vishay Dale
Inductors
Epoxy Conformal Coated
Uniform Roll Coated
FEATURES
• Flame-retardant coating.
• Color band identification.
• Excellent environmental characteristics.
• Uniform coating is excellent for automatic insertion.
• Comparable in quality to molded chokes at a lower price.
• Epoxy coating is more durable than lacquer coated
models, yet is priced comparably.
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Inductance Tolerance: ± 1%, ± 3%, ± 5%, ± 10%, ± 20%.
Terminal Strength: 5 pounds pull per MIL-STD-202,
Other tolerances available on request.
Method 211, Test Condition A.
Insulation Resistance: 1000 Megohm minimum per
Weight: IR-2 = 0.30 gram maximum.
MIL-STD-202, Method 302, Test Condition B.
IR-4 = 0.65 gram maximum.
Dielectric Strength: 1000 VAC per MIL-STD-202,
TEST EQUIPMENT*
• H/P 4342A Q-Meter.
Method 301.
MATERIAL SPECIFICATIONS
Coating: Epoxy-uniform roll coated.
Lead: Tinned copper.
• Measurements Corporation Megacycle Meter, Model 59.
• Wheatstone bridge.
*Test procedures per MIL-PRF-15305.
DIMENSIONS in inches [millimeters]
ENVIRONMENTAL PERFORMANCE
CONDITIONS
SPECIFICATIONS
TEST
Barometric
Pressure
MIL-STD-202,
Method 105
Test Condition C
A
1.25 [31.75] Min.
1.63 [41.28] Max.
Max.
Thermal Shock
Flammability
Overload
Test Condition A-1
—
MIL-STD-202,
Method 107
D
MIL-STD-202,
Method 111
C
B Max.
Max.
—
—
MIL-PRF-15305
MIL-PRF-15305
Low Temperature
Storage
MODEL
A (Max.)
B (Max.)
C (Max.)
D
IR-2
0.260
[6.60]
0.120
[3.05]
0.330
[8.38]
0.0200 ± 0.0015
[0.508 ± 0.038]
Resistance to
Soldering Heat
Test Condition A
—
MIL-STD-202,
Method 210
IR-4
0.180
[4.57]
0.440
0.025 ± 0.002
[0.635 ± 0.051]
0.385
[9.78]
Resistance to
Solvents
MIL-STD-202,
Method 215
[11.18]
MAXIMUM TEMPERATURE RISE
IR-2
OPERATING TEMPERATURE RANGE
0.1µH to 1.0µH = + 35°C @ + 90°C ambient.
1.2µH to 27µH = + 15°C @ + 90°C ambient.
33µH to 1000µH = + 15°C @ + 90°C ambient.
- 55°C to + 125°C
- 55°C to + 105°C
- 55°C to + 105°C
IR-4
0.15µH to 4.7µH = + 35°C @ + 90°C ambient.
5.6µH to 33µH = + 15°C @ + 90°C ambient.
36µH to 240µH = + 15°C @ + 90°C ambient.
270µH to 1800µH = + 35°C @ + 90°C ambient.
- 55°C to + 125°C
- 55°C to + 105°C
- 55°C to + 105°C
- 55°C to + 125°C
www.vishay.com
28
For technical questions, contact Magnetics@vishay.com
Document Number 34054
Revision 18-Oct-04