iQL Series
72-308W Quarter Brick Converter
Features
u Standard Quarter Brick Footprint
u 18-36, 36-75VDC Inputs
u 2.5V 60A, 28V 11A Nominal Outputs
u Through Hole Mounting
u 1500VDC Basic Isolation
u Baseplate cooling
u High operating efficiency (up to 93.5%)
u Constant switching frequency
Key Market Segments & Applications
Specifications
Model
IQL
Nominal Output Voltage
Input Voltage Range
VDC
VDC
2.5
3.3
5
8.3
12
28
See Model Selector
Ripple & Noise (max)(pk-pk)
Line Regulation (max)
Load Regulation (max)
(1) mV
mV
mV
A
(2) VDC
30
5
5
69
3.1
100
6.6
15
70
4.1
80
10
10
50
6.1
100
30
40
34
10
120
60
60
27.5
14.7
500
100
100
12.4
33.6
Overload Protection Threshold (3)
Overvoltage Protection (Typ)
Overtemperature Protection
Remote Sense
(3)
-
Yes
-
Yes
Yes
Yes
No
No(4)
No
Remote On / Off
Temperature (operating)
Temperature (storage)
Humidity (operating)
Humidity (storage)
Cooling
-
°C
°C
-
-
-
Negative Logic
-40 to 125 -40 to 119
-55 to 125
20 to 95% (non-condensing)
10 to 95% (non-condensing)
-40 to 115
-40 to 115
-40 to 118
-40 to 115
Conduction, convection, or forced air
Isolation Voltage
Vibration (non operating)
Shock
VDC
-
-
1500 Input - Output, 1500 Input - Baseplate
5 to 50Hz@0.5g (4.9m/s2), and 50 to 500Hz@1.5g (14.7m/s2) per BellcoreTR-EOP-000063-5.4.4
50 G at 6 ms pulse in three axes
Safety Agency Approvals
Weight (max)
Size
-
g
mm
yrs
UL60950 (US and Canada), VDE0805, CB scheme (IEC950), CE Mark (EN60950)
55g open frame, 70g with base plate
57.9 x 36.8 x 13.21
3 Years
Warranty
(1) See website for detailed specification and test methods.
(2) Latching
(3) Non-latching
(4) iQL24021A120V has remote sense
1-800-526-2324 • www.us.tdk-lambda.com/lp/
141