IE-XS-1W Series
FIXED INPUT,ISOLATED®ULATED Dual Output DC/DC Converter
SELECTION GUIDE
Input
Output
Current(MA)
Switching
Frequency
(KHz,Typ)
Efficiency
(%,Typ)
Voltage(VDC)
Voltage
(VDC)
Order code
Nominal
Range
Max
Min
IE0505XS-1W
IE0509XS-1W
IE0512XS-1W
IE0515XS-1W
IE1205XS-1W
IE1209XS-1W
IE1212XS-1W
IE1215XS-1W
IE2405XS-1W
IE2409XS-1W
IE2412XS-1W
IE2415XS-1W
5
4.75-5.25
4.75-5.25
4.75-5.25
4.75-5.25
11.4-12.6
11.4-12.6
11.4-12.6
11.4-12.6
22.8-25.2
22.8-25.2
22.8-25.2
22.8-25.2
±5
±9
±100
±56
±42
±33
±100
±56
±42
±33
±100
±56
±42
±33
±10
±6
69
61
62
64
72
61
63
64
72
60
63
64
83
83
5
5
±12
±15
±5
±5
83
FEATURES
5
±4
250
100
83
◆RoHS compliant
12
12
12
12
24
24
24
24
±10
±6
±9
◆Efficiency up to 86%
±12
±15
±5
±5
83
◆SIP10 Package
±4
83
±10
±6
83
◆Wide temperature performance at full
1 Watt load,-40°C to 85°C
◆UL 94V-0 package material
◆No heat sink required
±9
83
±12
±15
±5
83
±4
300
NOTICE:add Suffix “P” for Continuous Short Circuit Protection, e.g. IE0505XS-1WP
◆Low ripple and good EMC Features
◆Industry standard pin out
◆Power sharing on output
◆3KVDC isolation
◆Continuous Short Circuit Protection
ISOLATION SPECIFICATIONS
◆Internal SMD construction
Parameter
Test conditions
Flash tested for 1 minute and 1mA max
Test at Viso=500VDC
Min.
Typ.
Max.
Units
VDC
MΩ
◆No external components required
Isolation test voltage
Isolation resistance
3000
1000
◆Good dynamic feature
MODEL SELECTION
①
②
③
④
⑤
⑥
IE 05 05 X S -1W
①Product Series
③Output Voltage
⑤SIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
APPLICATIONS
The IE_XS-1W series are specially designed
for applications where a group of polar power
supplies are isolated from the input power
supply in a distributed power supply system on
a circuit board.
OUTPUT SPECIFICATIONS
Parameter
Output power
Test conditions
Min
0.1
Typ.
Max.
1
Units
W
These products apply to:
1) where the voltage of the input power supply
is fixed (voltage variation ≤±5%);
2) where isolation is necessary between input
and output (isolation voltage ≤3000VDC);
3) where the regulation of the output voltage
and the output ripple noise are demanded.
Line regulation
For Vin change of ±5%
10% to 100% full load
100% full load
±0.25
±1
%
Load regulation
%
Output voltage accuracy
Temperature drift
Output Ripple*
±3
%
100% full load
0.03
20
%/°C
MV p-p
MV p-p
Khz
20MHz Bandwidth
20MHz Bandwidth
Full load,nominal input
10
50
Output Noise*
100
Switching frequency
100
* Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing of Power
Converter section, application notes.
MICRODC RESERVES THE COPYRIGHT
http://www.microdc.cn
Technical Enquiries-Email:tech@microdc.cn Tel:0086-20-86000646
Page 1 of 2