IBU60 SERIES
63W Open frame switching power supplies for Industrial Equipment
Description:
The IBU60 series of compact, open frame constructed, AC/DC or DC/DC
switching mode power supplies provide 63 Watts of continuous output
power . They are ideally suited for use in CRT terminals, disc drive
systems, microprocess or based systems, portable equipments and
many other applications, all models are designed to meet the safety
requirements of UL/c-UL(UL 60950-1),TUV-Bauart(EN60950-1) and new
CE requirements. All units are 100% burned in and tested.
Features:
Wide Input Voltage 85 to 280 VAC, 47 to 400 Hz or 100 to 400VDC
Internal EMI filter
Single to Quad Output
Input connector mates with screw terminal (DINKLE#ESK750V-03P)
Output connector mates with Molex housing 09-50-3081 and
Molex 2478 series crimp terminal
Output Voltage Available From 3 VDC Thru 48VDC
Input Surge Current and Over Load protection
Over voltage protection (Crowbar Design)
Size: 3"x5"x1.1"
Safety Approvals :
Class I Insulation
Two Years Warranty
BAUART
GEPRUFT
Power Fail Detect (Optional)
TYPE
CB
APPROVED
Product Safety
Electrical Characteristics:
Sym.
Parameter
Test Conditions
Min. Typ. Max. Unit
90
106
85
264 VAC
350 VDC
280 VAC
400 VDC
400 Hz
Universal Input Voltage
Vin Input Voltage
Operating Voltage
100
47
Fin Input Frequency
Wo
Vo
Io
Output Power Range
Output Voltage Range
Output Current Range
Vin= Operating Voltage
0
63
W
See rating chart V
See rating chart A
Iil Input Current (Low Line)
Iih Input Current (High Line)
Io=Full load, Vin=115VAC or 160VDC
Io=Full load, Vin=230VAC or 325VDC
1.6
0.8
A
A
Io=Full load, 25°c, Cool start,
Irl Low Line Inrush Current
12
15
A
Vin=115VAC or 160VDC
Io=Full load, 25°c, Cool start,
Vin=230VAC or 325VDC
Irh High Line Inrush Current
26
30
A
Eff Efficiency
Io=Full Load, Vin=230VAC or 325VDC 70
Io=Full Load
80
0.5
3
88
1
%
%
%
%
%
REG-i Line Regulation
REG-o Load Regulation
OVP Over Voltage Protection
OCP Over Current Protection
Vin=230VAC or 325VDC
6
112
132
150
110
Io=Full Load to Half Load,
Vin=100VAC or 140VDC
Ttr Transient Response
5
mS
Thold Hold-Up Time
Ts Start Up Time
Io=Full Load, Vin=110VAC or 160VDC 16
Io=Full Load, Vin=100VAC or 140VDC 0.3
mS
S
1
1
2
2
Vrn Ripple & Noise (Peak to Peak) Full Load, Vin=85VAC or 100VDC
Ilk Safety Ground Leakage Current Io=Full Load, Vin=240VAC
%
0.4 0.45 mA
Tc
Temperature Coefficient
All output
-0.05 0.05
%/°c
Environmental :
Sym.
Typ.
Test Conditions
Parameter
Unit
Min.
Max.
Toper Operating Temperature
70
85
95
-20
-40
5
C
C
%
Tstg
Hr
Storage Temperature
Relative Humidity
Derate linearly from 100% load at 50 C to 50% load at 70 C
Pd
Safety Specifications:
Sym.
Parameter
Min. Typ. Max. Unit
Test Conditions
Dielectric Withstanding Voltage
Vps
VDC
Primary to secondary
4242
for Primary to secondary
Dielectric Withstanding Voltage
for Primary to Ground
Primary to ground
Vpg
Ri
2121
VDC
Isolation Resistance
Test Voltage=500VDC
Vin=220VAC
M
50
B
CISPR EMI requirements for CISPR-22
CLASS
CLASS
EMIrequirementsforFCCPART-15
FCC
Vin=110VAC
B