(888) IPD-CONVerters
ꢀ
(888) 473-2668
ꢀ
www.ipdconverters.com
IAS SERIES - 12 WATT
DESCRIPTION
FEATURES
IAS DC/DC converters provide up to 12 Watts of
output power in an industry standard package and
footprint. With a maximum case temperature of
100°C, the IAS is well suited for the most demanding
applications. The IAS features 1500 VDC isolation,
• Industry Standard
Package
• Industry Standard
Footprint
• Optional Trim and
Enable
• Wide Range Input
• 1500V Isolation
• Short Circuit Protection
• Up to 12W Output
short circuit, and overtemperature protection, as well • 100°C Case Operation
as six-sided shielding. The IAS is available with
optional enable and voltage trim. Please see the IAD
Efficiency vs. Load (24V Input)
series for dual output applications.
85
80
75
70
65
60
55
50
45
40
IAS010YG
EFF. (18v)
EFF. (24v)
EFF. (36v)
10
20
30
40
50
60
70
80
90
100
LOAD %
TECHNICAL SPECIFICATIONS
Input
General
Voltage Range
Turn-On Time
Remote Shutdown
Switching Frequency
Isolation
Input - Output
10 ms
Positive Logic
375 kHz
24 VDC Nominal
48 VDC Nominal
Reflected Ripple
18 - 36 VDC
34 - 75 VDC
25 mA
Input Reverse Input Current
Shunt Diode
1500 VDC
1050 VDC
Input - Case (24 Vin)
Output
Output - Case (48 Vin)
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Humidity Max., Non-Condensing
500 VDC
±0.03%/°C
Setpoint Accuracy
±1%
±0.2% Vout
Line Regulation Vin Min. - Vin Max., Iout Rated
Load Regulation Iout Min. - Iout Max., Vin Nom.
Minimum Output Current
-40 To +100°C
-55 To +115°C
95%
±0.5% Vout
10 % Iout Rated
Dynamic Regulation, Loadstep
25% Iout Vibration, 3 Axes, 5 Min Each
5 g, 10 - 55 Hz
2.1 X 106 hrs
UL, cUL, VDE
1.0 oz
MTBF† (Bellcore Tr-nwt-000332)
Pk Deviation
Settling Time
Voltage Trim Range
Short Circuit / Overcurrent Protection
4% Vout
500 µs
±10%
Safety
Weight (Approx.)
Shutdown / Hiccup
110 - 140%
Current Limit Threshold Range, % of Iout Rated
Notes
†
MTBF predictions may vary slightly from model to model.
Specifications typically at 25°C, normal line, and full load, unless otherwise stated.
Soldering Conditions: I/O pins, 260°C, ten seconds; fully compatible with
commercial wave-soldering equipment.
Safety: Agency approvals may vary from model to model. Please consult factory
for specific model information.
Units are water-washable and fully compatible with commercial spray or immersion
post wave-solder washing equipment.
C-10