Current Transducer HX 02..06-P
IPN = 2 .. 6 A
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
Electrical data
Primarynominal Primary current
Primary Conductor
Diameter x Turns
(mm)
Type
Features
r.m.s. current
measuring range
IPN (A)
IP (A)
· Galvanicisolationbetweenprimary
andsecondarycircuit
· Halleffectmeasuringprinciple
· Isolationvoltage 3000V
2
3
4
6
±6
±9
±12
±18
0.5d x 30T
0.6d x 20T
0.7d x 15T
1.0d x 10T
HX 02-P
HX 03-P
HX 04-P
HX 06-P
· Low power consumption
VOUT
ROUT
RL
VC
IC
Vd
Output voltage @ ± IPN, RL = 10 kW, TA = 25°C
Output impedance
Load resistance
Supply voltage (± 5 %)1)
Current consumption
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn > 3
R.m.s. voltage for partial discharge extinction
± 4
V
W
kW
V
mA
kV
· Extended measuring range(3x IPN
· Power supply from ±12V to ±15V
· Material according to UL94-V0
)
< 50
³ 10
± 15
< ± 15
Advantages
Ve
at 10pC
³ 1
³ 6
kV
kV
· Low insertion losses
· Easy to mount with automatic
handlingsystem
Impulse withstand voltage, 1.2/50µs
Accuracy-Dynamic performance data
· Small size and space saving
· Only one design for wide current
ratingsrange
· Highimmunitytoexternal
interference.
X
e
Accuracy @ IPN, TA = 25°C (without offset)
Linearity error (0 .. ± IPN)
< ± 1 % of IPN
< ± 1 % of IPN
L
VOE
VOH
Electrical offset voltage, TA = 25°C
Hysteresis offset voltage @ IP = 0;
after an excursion of 3 x IPN
< ± 40
mV
< ± 15
max. ± 1.5
± 0.1
mV
mV/K
%/K
µs
VOT
TCe
tr
Thermal drift of VOE
Thermal drift of the gain (% of reading)
Response time @ 90% of IP
Applications
G
£ 3
· Switched Mode Power Supplies
(SMPS)
2)
f
Frequency bandwidth (-3 dB)
50
kHz
· ACvariablespeeddrives
· UninterruptiblePowerSupplies
(UPS)
· Electricalappliances
· Batterysuppliedapplications
· DC motor drives
General data
TA
TS
m
Ambient operating temperature
Ambient storage temperature
Mass
Min. internal creepage distance/clearance
Isolation material group
Standards
- 25 .. + 85 °C
- 25 .. + 85 °C
8
g
³ 5.5
m m
I
EN50178
ApplicationDomain
· Industrial
Notes : 1) Also operate at ±12V power supplies, measuring range reduced to ±2.5x IPN
2)
Small signal only to avoid excessive heating of the magnetic cores
Page 1/2
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
060920/1