APPLICABLE STANDARD
OPERATING
STORAGE
-40 C TO +120 C
30
600 V AC/DC
-10 C TO +60 C (1)
TEMPERATURE RANGE
TEMPERATURE RANGE
CURRENT
RATING
A
STORAGE
HUMIDITY RANGE
RELATIVE HUMIDITY 85% MAX
(NOT DEWED)
VOLTAGE
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
VOLTAGE PROOF
10 A DC.
3 mΩ MAX.
3 mΩ MAX.
×
×
-
-
20 mV AC MAX, 10 mA(DC OR 1000Hz)
1000 V DC.
2200 V AC FOR 1 min.
100 MΩ MIN.
×
×
-
-
NO BREAKDOWN
1
1
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
① CONTACT RESISTANCE: 5 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
30 TIMES INSERTIONS AND EXTRACTIONS.
VIBRATION
FREQUENCY 20 TO 400Hz (43.1m/s2)
SWEEP TIME 3min.(ROUND TRIP)
AT 3h FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 7MIN ,
1s MIN.
② CONTACT RESISTANCE: 5 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
×
-
-
-
LOCK STRENGTH
MEASURE BREAK STRENGTH OF THE LOCK BY 98N MIN.
PULLING THE CONNECTOR IN THE MATING
DIRECTION.
×
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
① CONTACT RESISTANCE: 5 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
EXPOSED AT 60 C, 90 ~ 95 %, 96 h.
×
×
×
-
-
-
(STEADY STATE)
RAPID CHANGE OF
TEMPERATURE
① CONTACT RESISTANCE: 5 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
TEMPERATURE- 40 →ROOM TEMP →120C→
ROOM TEMP
×
×
×
-
-
-
TIME
30 →
5 → 30 → 5 min
UNDER 100 CYCLES.
DRY HEAT
EXPOSED AT 125C, 300 h.
EXPOSED AT -40C , 120 h.
① CONTACT RESISTANCE: 5 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
COLD
① CONTACT RESISTANCE: 5 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
RESISTANCE TO SO2 GAS
EXPOSED IN 25 PPM AT 75% MIN FOR 96h.
① CONTACT RESISTANCE: 5 m MAX.
×
×
×
-
-
-
RESISTANCE TO
SOLDERING HEAT
SOLDERABILITY
NO PLATING PEELING OF THE TERMINALS,
MELTINGS OF HOUSINGS.
SOLDER TEMPERATURE, 260℃ FOR
IMMERSION,DURATION,10s..
SOLDERED AT SOLDER TEMPERATURE 245C
FOR IMMERSION DURATION, 3s.
A NEW UNIFORM COATING OF SOLDER
SHALL COVER A MINIMUM OF 95 % OF
THE SURFACE BEING IMMERSED.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
YT.TAKANASHI
CHECKED
DATE
1
△
2
DIS-T-00019962
TY.MOGI
20240124
20180928
20180928
20180928
20180926
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
HK.UMEHARA
(NOTE1) "STORAGE" means a long-term storage state for the unused product.
AH.EDASHIGE
TS.SHIMIZU
DS.HIROWATARI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-374379-00-00
HVH-280-3P-6.5DS
SPECIFICATION SHEET
1
△
1/1
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
CL0778-0700-0-00