APPLICABLE STANDARD
OPERATING
STORAGE
-40 C TO 120 C
30 A
-10 C TO +60 C (1)
TEMPERATURE RANGE
TEMPERATURE RANGE
CURRENT
RELATIVE HUMIDITY 85% MAX
(NOT DEWED)
RATING
STORAGE
HUMIDITY RANGE
VOLTAGE
600 V AC/DC
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
10A DC.
3mΩ MAX
3mΩ MAX
×
×
-
-
2
CONTACT RESISTANCE
20 mV AC MAX, 10mA(DC OR 1000Hz)
2
MILLIVOLT LEVEL METHOD
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION 30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 5mΩMAX
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
MEASURE CONTACT RESISTANCE.
VIBRATION
FREQUENCY 20 TO 200Hz (88m/s2)
SWEEP TIME 3min.(ROUND TRIP)
AT 3h FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF
7MIN , 1s MIN.
② CONTACT RESISTANCE: 5mΩMAX
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
-
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
EXPOSED AT 85 C, 90 ~ 95 %, 96 h.
① CONTACT RESISTANCE: 5mΩMAX
② INSULATION RESISTANCE:100 MΩ MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
×
-
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE- 40 →ROOM TEMP →120C→ ① CONTACT RESISTANCE: 5mΩMAX
×
×
×
-
-
-
ROOM TEMP
TIME
② INSULATION RESISTANCE:100 MΩ MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
30 →
5 → 30 → 5 min
UNDER 1000 CYCLES.
DRY HEAT
COLD
EXPOSED AT 125C, 300 h.
① CONTACT RESISTANCE: 5mΩMAX
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
EXPOSED AT -40C , 120 h.
① CONTACT RESISTANCE: 5mΩMAX
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
×
×
-
-
RESISTANCE TO SO2 GAS EXPOSED IN 25 PPM AT 75% MIN FOR 96h.
CONTACT RESISTANCE:5mΩMAX
×
-
COUNT
2
DESCRIPTION OF REVISIONS
DIS-T-00003861
DESIGNED
TS.SHIMIZU
CHECKED
DATE
2
AH.EDASHIGE
HK.UMEHARA
20180928
20171129
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
.
(NOTE1) "STORAGE" means a long-term storage state for the unused product
HK.UMEHARA
KO.NAKAMURA
MN.SATOH
20171129
20171129
20171129
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-368755-00-00
DRAWING NO.
PART NO.
CODE NO.
HVH-280-1214PCF
CL778-0501-0-00
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
FORM HD0011-2-1
2
△
1/1