150W Single Output with PFC Function
HSP-150 series
Features :
Universal AC input / Full range
Withstand 300VAC surge input for 5 seconds
Built-in active PFC function
High efficiency up to 90%
Low leakage current<0.5mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection for 150W
and 200W with 30CFM forced air
Low profile:32mm
Conformal coated
ZVS technology to reduce power dissipation
Built-in remote sense
LED indicator for power on
3 years warranty
SPECIFICATION
MODEL
HSP-150-5
5V
HSP-150-3.8
HSP-150-2.5
DC VOLTAGE
3.8V
2.5V
30A
RATED CURRENT
30A
30A
0 ~ 30A
0 ~ 40A
150W
CURRENT RANGE(convection)
PEAK CURRENT RANGE(30CFM FAN)
RATED POWER(convection)
PEAK POWER(30CFM FAN)
RIPPLE & NOISE (max.) Note.2
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
0 ~ 30A
0 ~ 30A
0 ~ 40A
75W
0 ~ 40A
114W
200W
152W
100W
OUTPUT
100mVp-p
4.5~5.5V
2.0%
100mVp-p
80mVp-p
2.35~2.75V
3.4~4.2V
2.0%
2.0%
0.5%
0.5%
1.0%
0.5%
1.0%
LOAD REGULATION
1.0%
SETUP, RISE TIME
2000ms, 100ms/230VAC
3000ms, 100ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
127 ~ 370VDC
VOLTAGE RANGE
Note.4 90 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF 0.95/230VAC
PF 0.98/115VAC at full load
88%
INPUT
90%
86%
0.8A/115VAC
0.4A/230VAC
1.2A/115VAC
0.6A/230VAC
1.5A/115VAC
0.8A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Cold start 70A/230VAC
<0.5mA / 240VAC
140~180% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
PROTECTION
4.7 ~ 5.7V
Protection type : Shut down o/p voltage, re-power on to recover
110 (TSW1)
5.7 ~ 7.0V
3.2 ~ 3.7V
OVER VOLTAGE
5
115
5
(TSW1)
OVER TEMPERATURE
WORKING TEMP.
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-40 ~ +85 , 10 ~ 95% RH
0.03%/ (0 ~ 60
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1,EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC/25 / 70%RH
EMC
(Note 5)
Compliance to EN55022 (CISPR22) Class B,EN61000-3-2,EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11;EN55024, light industry level (surge 4KV), criteria A
EMC IMMUNITY
263.2K hrs min. MIL-HDBK-217F (25
220*62*32mm (L*W*H)
)
MTBF
OTHERS
NOTE
DIMENSION
0.61kg; 24pcs/15.6kg/1.63CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:HSP-150-SPEC 2012-03-07