Time Delay Relays
Dedicated - Vending
HRV SERIES
Coin Counter
Description
The HRV combines the accuracy of microcontroller based circuitry
with an electromechanical relay output.The HRV’s switching
capacity allows direct control of loads like compressors, pumps,
motors, heaters, and lighting.The HRV “S” version provides a
vend time after the selected number of initiate switch closures
to start is reached.The HRV “A” version includes all of the “S”
features and allows the total vend time to be extended for
each additional initiate switch closure.The HRV is ideal for cost
sensitive single coin or token vending machines.The electronic
circuitry is encapsulated to protect against humidity and vibration.
Operation
CoinTotalizer & VendingTimer (“S” Version):
Input voltage must be applied prior to & during operation.
When the total number of S1 initiate switch closures equals
the number to start set on the lower 3 DIP switches, the load
energizes and the vending time set on the upper 7 DIP switches
begins. At the end of the vending time, the load de-energizes
and the vending time is reset. Closing the initiate switch during
vend timing will have no affect on vend time delay.
Wiring Diagram
Accumulating VendingTimer (“A” Version):
L1
N/L2
Input voltage must be applied prior to and during operation.
When the total number of S1 initiate switch closures equals
the number to start set on the lower 3 DIP switches, the load
energizes and the vending time starts. For every initiate switch
closure, the HRV unit adds one time per coin period, as set on
the upper 7 DIP switches, to the total vending time.
ISOLATED
OUTPUT
Operation Note: If S1 is closed when input voltage is applied, the output remains de-energized
and the S1 counter remains at zero closures. At least one “vend time” and one “closures to start”
DIP switch must be in the “ON” position for proper operation.
V = Voltage
S1 = Initiate Switch
L = Load
Reset: Removing input voltage resets the vend time delay, the
S1 closure counter, and de-energizes the output relay.
UTL = Optional Untimed Load
L1
N/L2
Features & Benefits
FEATURES
BENEFITS
Repeat accuracy + / - 0.1%,
Setting accuracy 0 - 2%, or 50ms
NON-ISOLATED
OUTPUT
Microcontroller based
Encapsulated
Protects against shock, vibration, and humidity
30A , 1Hp at 125VAC,
normally open contacts
Allows direct control of loads like compressors,
pumps, motors, and heaters without a contactor
Switch selectable
coin start
Allows user flexibility to select the number of coins
to start vending cycle
Coin switch can be
connected to a counter
Provides user with accurate count of total number of
coins collected
Ordering Information
MODEL
INPUT VOLTAGE
VEND TIME
1 - 127s
MODE OF OPERATION
OUTPUT FORM & RATING
30A SPDT, NO (isolated)
30A SPDT, NO (isolated)
30A SPDT, NO (isolated)
30A SPDT, NO (isolated)
30A SPDT, NO (isolated)
30A SPDT, NO (isolated)
HRV11SC
HRV24AC
HRV41AE
HRV41SE
HRV42SE
HRV43AE
HRV43AN
HRV43SE
12VDC
Coin totalizer
Accumulating
Accumulating
Coin totalizer
Coin totalizer
Accumulating
Accumulating
Coin totalizer
24VAC
0.25 - 31.75m
1 - 127s
120VAC
120VAC
120VAC
120VAC
120VAC
120VAC
1 - 127s
5 - 635s
0.1 - 12.7m
0.1 - 12.7m
0.1 - 12.7m
30A SPDT, NO (non-isolated)
30A SPDT, NO (isolated)
If you don’t find the part you need, call us for a custom product 800-843-8848
© 2016 Littelfuse Protection Relays & Controls
www.littelfuse.com/hrv
Rev: 1-A-062316