Applicable standard
Operating
Storage
-40 °C to +90 °C ( 90 %RH Max.)
-40 °C to +90 °C ( 90 %RH Max.)
50 Ω( 0 t o 8 GHz)
temperature range
temperature range
Characteristic
impedance
Rating
-- W
----
Power
1
△
----
Peculiarity
Applicable cable
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General examination
Marking
Visually and by measuring instrument.
Confirmed visually.
According to drawing.
X
-
X
-
ELECTRICAL CHARACTERISTICS
Contact resistance
100 mA Max.(DC or 1000 Hz)
Center contact 14 mΩ Max.
Outer contact 14 mΩ Max.
500 MΩ Min.
X
X
X
X
X
X
X
X
Insulation resistance
100 V DC.
Withstanding voltage
Voltage standing
wave ratio
200 V AC for 1 min. current leakage 2 mA Max.
Frequency 0 to 6 GHz.
Frequency 6 to 8 GHz.
Frequency - to - GHz.
No flashover or breakdown.
VSWR 1.3 Max.
X
-
-
-
1
△
VSWR 1.4 Max.
--- dB Max.
Insertion loss
MECHANICAL CHARACTERISTICS
Contact Insertion and
extraction forces
After 3 times mating with oversized
Insertion force
8.9 N Max.
X
X
X
X
gauge: φ 0.9525+0.0025 and measure by use of
following gauge. 0
Insertion force gauge : φ0.9398
+0.0025
0
Extraction force 0.3 N Min.
Insertion force --- N Max.
0
Extraction force gauge : φ0.9017-0.0025
Insertion and
Measured by applicable connector.
-
-
-
-
extraction forces
Mechanical operation
Extraction force --- N Min.
1)Contact resistance:
500 times insertion and extractions.[HRM Side]
30 times insertion and extractions.[U.FL Side]
Center contact 21 mΩ Max.
Outer contact 21 mΩ Max.
X
-
2)No damage, crack and looseness of parts.
1)No electrical discontinuity of 1 μs.
2)No damage, crack and looseness of parts.
Vibration
Shock
Frequency 10 to 100 Hz single amplitude 1.5 mm,
59 m/s2 at 5 cycles for 3 directions.
X
X
-
-
735 m/s2 directions of pulse 11 ms
at 3 times for 3 directions.
Cable clamp strength
(Against cable pull)
Using a pulling tester, pull the cable axially at a rate
of - mm/min. and record the strength at which
the cable or connector breaks.
--- N Min.
-
-
ENVIRONMENTAL CHARACTERISTICS
Damp heat
Exposed at +40 °C, 95 %
total cycles.( 96 h)
1)Insulation resistance: 100 MΩ Min.
(at high humidity)
-
2) Insulation resistance: 500 MΩ Min.
(at dry)
X
-
3)No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
Rapid change of
temperature
Temperature
Time
-40 →
5-35→+90→5-35 ℃
X
X
-
-
30 →
3 → 30 →
3
min.
Under 5 cycles.
Exposed in 5 % salt water spray for 48 h.
Corrosion salt mist
VSWR 1.3 Max.
Count
2
Description of revisions
DIS-D-00004891
Designed
NK.NINOMIYA
Checked
TS.NOBE
Date
20200428
1
△
TO.KATAYAMA
TO.KATAYAMA
YI.FUNADA
20170529
Remark
Approved
Checked
Designed
Drawn
20170529
20170529
20170529
YI.FUNADA
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
Part No.
ELC-317236-00-00
HRMJ-U.FLJ-PC-1
SPECIFICATION SHEET
1
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
CL311-0432-3-00
△
FORM HD0011-2-1