Applicable standard
Operating
Storage
-55 °C to +125 °C ( 95 %RH Max.)
-55 °C to +125 °C ( 95 %RH Max.)
temperature range
temperature range
Characteristic
impedance
Applicable
cable
-- W
----
50 Ω( 0 to 18 GHz)
Rating Power
----
Peculiarity
SPECIFICATIONS
ITEM
CONSTRUCTION
General examination
Marking
TEST METHOD
REQUIREMENTS
According to drawing.
QT AT
Visually and by measuring instrument.
Confirmed visually.
X
-
X
-
ELECTRICAL CHARACTERISTICS
Contact resistance
100 mA Max.(DC or 1000 Hz)
Center contact 10 mΩ Max.
Outer contact 10 mΩ Max.
1000 MΩ Min.
X
X
X
X
X
-
X
X
X
X
X
-
Insulation resistance
Withstanding voltage
Return loss
500 V DC.
500 V AC for 1 min. current leakage 2 mA Max.
Frequency 0 to 18 GHz.
Frequency - to - GHz.
No flashover or breakdown.
Return loss
--- dB Max.
20 dB Min.
Insertion loss
MECHANICAL CHARACTERISTICS
Contact insertion and
extraction forces (HRM)
Contact insertion and
extraction forces (SMP)
Insertion and
φ 0.91 +0.005 by steel gauge.
Insertion force
--- N Max.
-
X
-
X
0
Extraction force 1.5 N Min.
Insertion force --- N Max.
Extraction force 0.2 N Min.
Insertion force --- N Max.
0
φ 0.35 - 0.005 by steel gauge.
-
X
-
X
Measured by applicable connector.
500 times insertion and extractions.
-
-
-
-
extraction forces
Extraction force --- N Min.
1)Contact resistance:
Mechanical operation
Center contact 18 mΩ Max.
Outer contact 18 mΩ Max.
X
-
2)No damage, crack and looseness of parts.
Vibration
Shock
Frequency 10 to 500 Hz single amplitude 0.75 mm, 1)No electrical discontinuity of 1 μs.
X
X
-
-
98 m/s2 at 10 cycles for 3 directions.
490 m/s2 directions of pulse 11 ms
at 3 times for 3 directions.
2)No damage, crack and looseness of parts.
Cable clamp strength
(Against cable pull)
Using a pulling tester, pull the cable axially at a rate
N Min.
of
mm/min. and record the strength at which
-
-
the cable or connector breaks.
ENVIRONMENTAL CHARACTERISTICS
Damp heat
1)Insulation resistance: 100 MΩ Min.
Exposed at -10 to +65 °C, 90~98 %
total 10 cycles.( 240 h)
(at high humidity)
X
2) Insulation resistance: 1000 MΩ Min.
(at dry)
-
3)No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
Rapid change of
temperature
Temperature
Time
-65 →
-
→+125 → - °C
→30 → 3 min.
X
X
30 →
3
-
-
Under 5 cycles.
Corrosion salt mist
Exposed in 5 % salt water spray for 48 h.
Description of revisions
Return loss
20 dB Min.
Count
Designed
Checked
Date
0
△
KY.SHIMIZU
KY.SHIMIZU
TY.OZAKI
17.02.21
17.02.21
17.02.21
17.02.21
Remark
Approved
RoHS COMPLIANT
Checked
Designed
Drawn
TY.OZAKI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
Part No.
ELC-364323-00-00
SPECIFICATION SHEET
HRMJ-SMPJ-BPA-18G
0
△
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
CL311-0001-0-00
FORM HD0011-2-1