Description
The HRDR Series combines an electromechanical relay and
microcontroller timing circuitry. It offers 12 to 230V operation in
five ranges and factory fixed, onboard or externally adjustable
time delays with a repeat accuracy of 0.ꢀ5. The high switching
capacity of the output contacts allow for direct control of heavy
loads like compressors, pumps, motors, heaters and lighting. A
bypass/reset switch option allows operator to interrupt normal
recycling sequence and energize output relay. An excellent
choice for OEM applications.
Operation (Recycling with Reset Switch)
Upon application of input voltage, the ON timeT1 begins and
output relay energizes. At the end of the ON time, the output
relay de-energizes and the OFF timeT2 begins. At the end of the
OFF time, the output relay energizes and the cycle repeats as
long as input voltage is applied. Some recycling timers have the
OFF time as the first delay.
Reset: Removing input voltage resets output and time delays,
and returns sequence to the first delay.
Wiring Diagram
Bypass/Reset Switch: Closing the normally open bypass/reset
switch energizes the output relay and resets the time delays.
Opening the switch restarts recycling operation with the
first delay.
L1
N/L2
NO = Normally Open
S1 = Reset Switch
C = Common,Transfer Contact
L = Load
Features & Benefits
Terminals 4 & 5 and/or 7 & 8
are only included on externally
adjustable units. Relay
FEATURES
BENEFITS
Microcontroller based
Repeat Accuracy + / - 0.5%
contacts are non-isolated.
Compact, low
cost design
R
is included when external
Allows flexiblility for OEM applications
T
adjustment is ordered.
Isolated, 30A, SPDT,
NO output contacts
Allows direct operation of heavy loads:
compressors, pumps, blower moters, heaters.
Terminal 6 is included when
Bypass/Reset is selected.
Encapsulated
Protects against shock, vibration, and humidity
Independent adjustment
of On and Off delays
Provides greater flexibility of timing options
Bypass/Reset
switch option
Allows operator to interrupt the timing sequence
and energize the output relay
Ordering Information
INPUT
OPERATING
BYPASS / RESET
MODEL
EXTERNAL ADJUSTMENT
T1 ON TIME
T2 OFF TIME
OPTION
VOLTAGE
SEQUENCE
On time first
On time first
Off time first
On time first
On time first
Off time first
On time first
HRDR121A4R
HRDR321A4R
HRDR322B2R
HRDR330A0R
HRDR331A1
12VDC
24VDC
24VDC
24VDC
24VDC
120VAC
120VAC
Both time onboard adj
Both time onboard adj
Both time onboard adj
Both time external adj
Both time external adj
Both times fixed
1 - 100s
1 - 100s
10 - 1000S
0.1 - 10s
1 - 100s
1s
1 - 100m
1 - 100m
10 - 1000S
0.1 - 10s
1 - 100s
30m
Yes
Yes
Yes
Yes
No
HRDR411SB30MR
HRDR431A1R
Yes
Yes
Both times external adj
0.1 - 100s
0.1 - 100s
If you don’t find the part you need, call us for a custom product 800-843-8848