APPLICABLE STANDARD
Operating
Temperature Range
Storage Temperature
Range
-40C to
+105C (2)
-10C to
+60C
Rating
Voltage
―
①
②
0.52~1.31 mm2
AWG#16~#20
Applicable Cable(1)
1
10A (UL, TÜV)
Current(4)
1
Jacket Diameter φ1.9~3.2
13A(Ambient Temperature 25C)
SPECIFICATIONS
TEST METHOD
ITEM
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
According to the drawing.
X
X
X
X
Marking
ELECTRICAL CHARACTERISTICS
Contact Resistance
Measured at DC 1A.
5 M MAX.
X
X
X
MECHANICAL CHARACTERISTICS
Contact Insertion and
Measured with a φ1.57 ± 0.003 steel gauge.
Insertion and extraction forces: 0.5 N MIN.
-
Extraction Forces
1
Basic Curve
Derating Curve
3) The derating curve is derived from the basic
curve multiplied by the derating factor of 0.8.
4) The value of rated current varies with the ambient
temperature. It is recommended to use the product
within the derating curve zone.
When using a UL or TÜV approved product, please
use the product within the specified range as well as
the derating curve area.
5) The measurement method of the derating curve is
shown below.
•Test specimen: This product, unused prior to
testing.
•Test cable conductor cross sectional area:
AWG16 (1.31mm2)
•Test condition: Power supplied while the
specimen is in a stationary state and then
measured.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
HY.KOBAYASHI
EJ.KUNII
DATE
3
DIS-C-00001411
TY.SUZUKI
17.01.30
15.01.22
15.01.22
15.01.22
15.01.22
△
0
Notes
APPROVED
CHECKED
DESIGNED
DRAWN
1) The applicable cable should satisfy both conditions ① and ②
HY.KISHI
2) Includes temperature rise due to current carrying.
HN.TANAKA
HN.TANAKA
Unless otherwise specified, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-118232-01-00
HR41A-SC-211(01)
CL141-0206-0-01
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
1/1
△
0
FORM HD0011-2-1