APPLICABLE STANDARD
Operating
Storage Temperature
Range
-40C to
+105C
-10C to
+60C
Temperature Range(2)
Voltage
Current(1)
Rating
―
AC, DC 1000 V
13A(ambient temperature 25℃)
―
Applicable Cable
Φ9.9~10.7
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
Contact Resistance
Measured at DC 1A.
5 m MAX.
Insulation Resistance
Voltage Proof
Measured at 500 V DC.
5000 M MIN.
X
X
X
X
X
2200 V AC applied for 1 min.
No flashover or breakdown.
-
Impulse Voltage Proof
Subjected to a standard waveform of 15kV in mated condition No flashover or breakdown.
(1.2/50μs waveform, applied in both positive and negative
polarities 3 times each).
MECHANICAL CHARACTERISTICS
Contact Insertion and
Measured with a φ1.57±0.003 steel gauge.
Insertion and extraction forces: 0.5 N MIN.
X
X
-
-
Extraction Forces
Mating and
Mating and unmating forces: 100 N MAX.
Measured with an applicable connector.
Unmating Forces
Contact Retention Force
Subjected to a 20N force from the wiring side.
Mated and unmated 500 times.
No movement of contact.
X
X
-
-
Mechanical Operation
Vibration
Contact resistance: 10 m MAX.
Frequency: 10 Hz to 55 to 10 Hz every cycle (5 min per cycle) 1) No electrical discontinuity of more than 10 s.
Single amplitude: 0.75 mm
X
-
2) No damage, cracks or looseness of parts.
Performed over 10 cycles in each of three mutually
perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
Performed 3 times in each of three mutually perpendicular
directions.
1) No electrical discontinuity of more than 10 s.
X
-
2) No damage, cracks or looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Rapid Change of Temperature Temperature: -40 → R/T(3) → +105 → R/T C
Time: 30 → 2 to 3 → 30 → 2 to 3 min
1) Insulation resistance: 500 M MIN.
X
X
-
-
2) No damage, cracks or looseness of parts.
for 5 cycles.
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
1) Insulation resistance: 50 M MIN.
(At high humidity)
95% for 96 hours.
2) Insulation resistance: 500 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
No heavy corrosion which impairs functionality.
Corrosion Salt Mist(4)
Dry Heat
X
X
Subjected to 5% salt spray for 48h.
-
-
Subjected to +105℃ for 96h.
Subjected to -40℃ for 96h.
No damage, cracks or looseness of parts.
No damage, cracks or looseness of parts.
Cold
X
-
Sealing(4)
Subjected to a depth of 2 m for 14 days.
No water penetration to the inside of the
connector.
X
-
Air Tightness(4)
17.6kPa applied to the inside of the connector for 0.5min.
No air bubbles from the inside of the connector.
X
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
DIS-A-00065601
0
△
NOTES
APPROVED
CHECKED
DESIGNED
DRAWN
TP.KOMATSU
20220301
20220301
20220228
20220228
(1) The above specifications show the values in assembled condition with applicable
crimp contacts. (applicable crimp contact:HR41A-SC-111)
EJ.KUNII
SH.KOYAMA
SH.KOYAMA
(2) Including temperature rise due to current carrying.
(3) R/T:Room Temperature.
(4) Corrosion salt mist, sealing and airtightness are tested in mated condition with an
applicable connector.
Unless otherwise specified, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-118872-81-00
HR41A-17WBPAF-5SC(81)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL0141-0228-2-81
FORM HD0011-2-1