APPLICABLE STANDARD
Operating
Storage Temperature
Range
-40C to
+105C
-10C to
+60C
Temperature Range (2)
Voltage
Current(1)
Rating
―
AC, DC 1000 V
―
Applicable Cable
―
Φ9.0~9.8
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument.
Confirmed visually.
X
X
X
X
According to the drawing.
Marking
ELECTRICAL CHARACTERISTICS
X
X
Contact Resistance
Measured at DC 1A.
5 m MAX.
Insulation Resistance
Voltage Proof
Measured at 500 V DC.
5000 M MIN.
X
X
X
X
X
2200 V AC applied for 1 min.
No flashover or breakdown.
-
Impulse Voltage Proof
Subjected to a standard waveform of 15kV in mated condition No flashover or breakdown.
(1.2/50μs waveform, applied in both positive and negative
polarities 3 times each).
MECHANICAL CHARACTERISTICS
Contact Insertion and
Measured with a φ___ steel gauge.
Insertion and extraction forces: - N MIN.
-
-
-
Extraction Forces
Mating and
Mating and unmating forces: 100 N MAX.
Measured with an applicable connector.
X
Unmating Forces
Contact Retention Force
Subjected to a 20N force from the wiring side.
Mated and unmated 500 times.
No movement of contact.
X
X
-
-
Mechanical Operation
Vibration
Contact resistance: 10 m MAX.
Frequency: 10 Hz to 55 to 10 Hz every cycle (5 min per cycle) 1) No electrical discontinuity of more than 10 s.
Single amplitude: 0.75 mm
X
-
2) No damage, cracks or looseness of parts.
Performed over 10 cycles in each of three mutually
perpendicular directions.
Shock
Acceleration: 490 m/s2, Half sine wave pulses of 11 ms.
Performed 3 times in each of three mutually perpendicular
directions.
1) No electrical discontinuity of more than 10 s.
X
-
2) No damage, cracks or looseness of parts.
ENVIRONMENTAL CHARACTERISTICS
Rapid Change of Temperature Temperature: -40 → R/T(3) → +105 → R/T C
Time: 30 → 2 to 3 → 30 → 2 to 3 min
1) Insulation resistance: 500 M MIN.
X
X
-
-
2) No damage, cracks or looseness of parts.
for 5 cycles.
Damp Heat, Steady State
Subjected to a temperature of +40C, at a humidity of 90 to
1) Insulation resistance: 50 M MIN.
(At high humidity)
95% for 96 hours.
2) Insulation resistance: 500 M MIN. (When dry)
3) No damage, cracks or looseness of parts.
No heavy corrosion which impairs functionality.
Corrosion Salt Mist(4)
Dry Heat
X
X
Subjected to 5% salt spray for 48h.
-
-
Subjected to +105℃ for 96h.
Subjected to -40℃ for 96h.
No damage, cracks or looseness of parts.
No damage, cracks or looseness of parts.
Cold
X
-
Sealing(4)
Subjected to a depth of 2 m for 14 days.
No water penetration to the inside of the
connector.
X
-
Air Tightness(4)
COUNT
17.6kPa applied to the inside of the connector for 0.5min.
No air bubbles from the inside of the connector.
X
-
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
DIS-A-00065601
0
△
NOTES
APPROVED
CHECKED
DESIGNED
DRAWN
TP.KOMATSU
20220301
20220301
20220228
20220228
(1) The above specifications show the values in assembled condition with applicable
crimp contacts.
(2) Including temperature rise due to current carrying.
EJ.KUNII
SH.KOYAMA
SH.KOYAMA
(3) R/T:Room Temperature.
(4) CORROSION SALT MIST, SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER
MATED CONDITION WITH AN APPLICABLE CONNECTOR.
Unless otherwise specified, refer to IEC 60512 (JIS C 5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-389361-81-00
PART NO.
CODE NO.
HR41A-17WBPAB-3PC(81)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
1/1
CL0141-0232-0-81
△