APPLICABLE STANDARD
Operating
Storage Temperature
Range
-40 C TO
+105 C
-10
C TO
+60 C
Temperature Range (2)
RATING
①Conductor area:5.5 to 6.5 mm2
(AWG#10 corresponding )
Voltage
Current (4)
Applicable Cable (1)
20A(UL, TÜV)
24A(Ambient Temperature 25C)
②Conductor diameter : φ3.4 MAX
③Jacket diameter : φ6 MAX
4
△
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Examined visually and with a measuring instrument. According to the drawing.
Confirmed visually.
X
X
X
X
Marking
ELECTRICAL CHARACTERISTICS
Contact Resistance
Measured at DC 1 A MAX
X
X
X
2
m MAX.
MECHANICAL CHARACTERISTICS
Contact Insertion and
Extraction Forces
Insertion and extraction force 0.8 N MIN.
Measured with a φ3.58±0.003 steel gauge.
-
4
△
Basic Curve
Darating Curve
Notes (3) The derating curve is derived from the basic curve multiplied by the derating factor of 0.8.
(4) The value of rated current varies with the ambient temperature.
It is recommended to use the product within the derating curve zone.
When using a UL or TÜV approved product, please use the product within the specified range as well as
the derating curve area.
(5) The measurement method of the derating curve is shown below.
• Test specimen: This product, unused prior to testing.
• Test cable conductor cross sectional area : AWG#10 (5.5mm2)
• Test condition: Power supplied while the specimen is in a stationary state and then measured.
COUNT
2
DESCRIPTION OF REVISIONS
DIS-C-00001396
DESIGNED
TY.SUZUKI
CHECKED
HY.KOBAYASHI
SU.OBARA
DATE
17.01.30
11.09.01
11.09.01
11.08.31
4
Notes
APPROVED
CHECKED
DESIGNED
DRAWN
(1) The applicable cable should satisfy all conditions ① to ③.
HY.KOBAYASHI
HT.ZENBA
(2) Includes temperature rise due to current carrying.
Unless otherwise specified, refer to IEC 60512(JIS C 5402)
HT.ZENBA
11.08.31
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC4-117588-01
HR41-SC-141(01)
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
4
△
1/1
CL141-0008-6-01
FORM HD0011-2-1