VRLA Rechargeable Battery
Measures
Technology
Values
Innovation
HR33-12
FEATURES
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Electronic Medical Equipment
Wheelchairs
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
Lawn Mowers
UPS
Golf-Carts
The battery is designed for high rate usage.
Absorbent Glass Mat technology for efficient gas recombination.
The power density at 5 min~15min discharging rate is 30% higher
than BP series.
SPECIFICATIONS
Nominal Voltage
12 V
31Ah @ 10 hour rate F.V.(1.75V/cell)
10.0Kg(22.05lbs.)
Nominal Capacity
Approx. Weight
B1 (Fitting M5 bolt & nut) , T2 and I1 are optional
Terminals
(Fully Charged )
7m
Internal Resistance
Max. Discharge Current
Max. Charge Current
420 A (5 sec.)
9.30 A
Charge 0 C~40 C(32 F~104 F)
o
o
o
o
Operating Temperature Range
o
o
o
o
Discharge -20 C~50 C(-4 F~122 F)
o
o
o
o
Storage. -20 C~40 C(-4 F~104 F)
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
Container Material
HR33-12
Optional: Flame Retardant ABS(UL 94-V0)
Standard: ABS( UL 94-HB)
HR33-12FR
DIMENSION(mm/inch)
Length
OUTER DIMENSIONS
TERMINAL TYPE
(6.89±0.06)
175±1.5
Terminal B1
Terminal T2
Terminal I1
Width
3.4(0.13)
M5x0.8
12.0(0.47)
2.0(0.08)
(6.54±0.06)
166±1.5
Container Height
7.95(0.31)
(4.92±0.06)
125±1.5
[M5 BOLT & NUT]
[M5 BOLT & NUT]
Total Height
(4.92±0.06)
Terminal Hardware Initial Torque: B1(2.5Nm±5%),I1(4.0Nm±5%)
125±1.5
o
o
Constant power discharge characteristics at 25 C/77 F
Unit: W
Discharge
F.V.
Time
5 Min
10 Min
15 Min
20 Min
30 Min
40 Min
50 Min
60 Min
120 Min
(V/cell)
1353.0
1617.0
1733.0
1782.0
1815.0
1832.0
924.0
1031.0
1085.0
1106.0
1120.0
1130.0
669.0
728.0
761.0
777.0
786.0
792.0
571.0
605.0
627.0
637.0
643.0
647.0
434.0
452.0
462.0
468.0
471.0
330.0
342.0
351.0
355.0
357.0
359.0
276.0
285.0
290.0
294.0
296.0
298.0
243.0
248.0
252.0
255.0
257.0
257.0
133.8
136.4
138.6
139.3
139.7
140.1
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
474.0
o
o
Unit: W
Unit: A
Constant current discharge characteristics at 25 C/77 F
Discharge
F.V.
Time
5 Min
10 Min
15 Min
20 Min
30 Min
40 Min
50 Min
60 Min
120 Min
(V/cell)
120.80
147.00
157.55
162.00
165.00
166.55
81.05
90.44
95.18
97.02
98.25
99.12
57.87
62.98
65.83
67.21
67.99
68.51
48.97
51.89
53.77
54.63
55.15
55.49
36.78
38.31
39.15
39.66
39.92
40.17
27.75
28.76
29.52
29.86
30.03
30.19
23.10
23.85
24.27
24.60
24.77
24.94
20.25
20.67
21.00
21.25
21.42
21.42
11.15
11.37
11.55
11.61
11.64
11.68
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/3 REV. Dec. 2013
Powered by B.B. Battery Co., Ltd.