APPLICABLE STANDARD
-25 C TO
+85 C
-10
C TO
+60 C
OPERATING
STORAGE TEMPERATURE
RANGE
RATING
TEMPERATURE RANGE
VOLTAGE
AC 100 V , DC 140 V
2 A
CURRENT
APPLICABLE CABLE
φ4.2 TO φ5
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
X
X
X
X
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
15 m MAX.
1000 M MIN.
X
X
X
X
X
X
CONTACT RESISTANCE
INSULATION RESISTANCE
VOLTAGE PROOF
CONTACT SHALL BE MEASURED AT DC
1
A
100
300
V DC.
V AC. FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES :
INSERTION AND WITHDRAWAL FORCES
N MIN.
-
-
CONNECTOR INSERTION AND
WITHDRAWAL FORCES
MEASURED BY APPLICABLE CONNECTOR.
X
X
-
-
LOCKING DEVICE WITH LOCK
: 30 N MAX.
MECHANICAL OPERATION
VIBRATION
CONTACT RESISTANCE:
30
m MAX.
1000 TIMES INSERTIONS AND EXTRACTIONS.
①NO ELECTRICAL DISCONTINUITY OF 10 s.
FREQUENCY: 10 → 55 → 10 (Hz) (1CYC,5min),
X
-
SINGLE AMPLITUDE 0.75 mm, AT 10 CYC, FOR 3 DIRECTIONS. ②NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
SHOCK
490 m/s2 DURATIONS OF PULSE 11 ms AT 3 TIMES
FOR 3 DIRECTIONS.
X
X
-
-
BREAKING STRENGTH
MAX 30N SHALL BE APPLIED TO CABLE IN UP AND DOWN,
LEFT AND RIGHT DIRECTIONS WHEN MATED.
NO BREAKAGE MAX 30N.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
① INSULATION RESISTANCE: 10 MΩ MIN
(AT HIGH HUMIDITY).
(STEADY STATE)
X
X
-
-
② INSULATION RESISTANCE: 100 MΩ MIN (AT DRY).
③ NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
① INSULATION RESISTANCE: 100 MΩ MIN.
② NO DAMAGE.CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF TEMPERATURE TEMPERATURE -55→ R/T(1) → +85 → R/T ℃
TIME 30 → 10 TO 15 → 30 → 10 TO 15 min
UNDER 5 CYCLES.
NO HEAVY CORROSION RUINS THE FUNCTION.
EXPOSED IN 5 SALT WATER SPRAY FOR 48 h.
X
X
X
CORROSION SALT MIST
-
-
-
DRY HEAT
COLD
EXPOSED AT + 85 ℃ , 96 h.
EXPOSED AT - 55 ℃ , 96 h.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
NO DAMAGE,CRACK AND LOOSENESS OF PARTS.
RESISTANCE TO SOLDERING
HEAT
SOLDER TEMPERATURE, + 380±10℃, FOR SOLDERING
DURATION, 3 TO 4 s.
NO DEFORMATION OF CASE OF EXCESSIVE LOOSENESS
OF THE TERMINALS.
X
-
SOLDERABILITY
SOLDERED AT SOLDER TEMPERATURE, + 350±10℃ FOR
SOLDERING DURATION, 2 TO 3 s.
WETTING ON SOLDER SURFACE,NO SOLDER CLUSTER.
X
X
X
-
-
-
SEALING(2)
EXPOSED AT A DEPTH OF 2 m FOR 14 DAYS.
NO WATER PENETRATION INSIDE CONNECTOR.
NO AIR BUBBLES INSIDE CONNECTOR.
AIRTIGHTNESS(2)
APPLY AIR PRESSURE 17.6kPa FOR 0.5min TO INSIDE
CONNECTOR.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
△
0
REMARK
NOTES(1)R/T : ROOM TEMPERATURE
APPROVED
CHECKED
DESIGNED
DRAWN
HY.KOBAYASHI
18.02.26
HY.KOBAYASHI
DS.MATSUNE
18.02.26
18.02.24
18.02.22
(2)SEALING AND AIRTIGHTNESS SHALL BE TESTED UNDER MATED CONDITION WITH
AN APPLICABLE CONNECTOR.
AI.NISHIYAMA
Unless otherwise specified, refer to IEC 60512(JIS C5402).
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
ELC-112010-31-00
HR30-6P-6P(31)
PART NO.
CODE NO.
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL130-0009-5-31
FORM HD0011-2-1