RoHS Compliant ALUMINIUM ELECTROLYTIC CAPACITOR
HR Series
ꢀ
ꢀ
FEATURES
◆
◆
Load life of 5000 hours at 105°C
Applications for switching power supplies
◆
Low impedance and low ESR with high ripple current
OUTLINE
mm
D
F
d
8
10
13
16
18
5.0
7.5
0.8
3.5
0.6
ꢀ
SPECIFICATIONS
Items
Characteristics
Capacitance Tolerance
(120Hz, 25°C)
± 20% (M)
Rated Working Voltage Range
Operation Temperature
10 ~ 100Vdc
-40°C ~ +105°C
(After 3 minutes applying the DC working voltage)
Leakage Current (25°C)
Surge Voltage (25°C)
I ≤ 0.01CV
◆ I : Leakage Current (u A)
◆ C : Rated Capacitance (u F)
◆ V : Working Voltage (V)
W.V.
S.V.
10
13
16
20
25
32
35
44
50
63
63
79
100
125
100
W.V.
tan δ
10
16
25
35
50
63
Dissipation Factor (120Hz, 25°C)
0.12
0.10
0.09
0.08
0.07
0.06
0.06
◆ For capacitance exceeding 1000 u F, add 0.02 per increment of 1000 u F
W.V.
- 25°C / + 25°C
10 ~ 16
25 ~ 100
3
6
2
4
Temperature Characteristics
- 40°C / + 25°C
◆ Impedance ratio at 120Hz
After 2000 hours application of WV at +105°C, the capacitor shall meet the following limits:
(3000 hours for 10φ and 13φ, 5000 hours for 16φ and larger)
Load Test
Capacitance Change
tan δ
≤ ± 25% of initial value
≤ 150% of initial specified value
≤ initial specified value
Leakage Current
After 1000 hours, no voltage applied at +105°C, the capacitor shall meet the following limits:
Capacitance Change
tan δ
≤ ± 25% of initial value
Shelf Test
≤ 150% of initial specified value
≤ 200% of initial specified value
Leakage Current
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Qubec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com