APPLICABLE STANDARD
OPERATING
RATING TEMPERATURE RANGE
VOLTAGE
STORAGE
-15
℃
TO
+60
℃
-15
℃
TO
+60
℃
TEMPERATURE RANGE
AC 100 V , DC 140
V
1
A
CURRENT
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
○
○
○
○
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE(1)
CONTACT SHALL BE MEASURED AT DC
1
A
292 mΩ MAX.
112 mΩ MAX.
○
○
○
○
○
○
○
○
GROUND SHALL BE MEASURED AT DC
250 V DC.
1
A
INSULATION RESISTANCE
VOLTAGE PROOF
200 MΩ MIN.
300 V AC
FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
WITHDRAWAL FORCES
CONNECTOR INSERTION
BY STEEL GAUGE.
INSERTION AND WITHDRAWAL FORCES :
N
-
○
-
-
MEASURED BY APPLICABLE CONNECTOR.
INSERTION AND WITHDRAWAL FORCES :5 TO
50 N.
AND WITHDRAWAL FORCES LOCKING DEVICE.
MECHANICAL OPERATION
1000 TIMES INSERTIONS AND EXTRACTIONS.
CONTACT RESISTANCE: 302
mΩ MAX.
○
○
-
-
GROUND RESISTANCE: 132
mΩ MAX.
VIBRATION
FREQUENCY: 10 TO 55 Hz,SINGLE AMPLITUDE 1.5 mm, 1)NO ELECTRICAL DISCONTINUITY OF 1 μs.
m/s2 AT 2h, FOR 3 DIRECTIONS.
2)NO DAMAGE, CRACK AND LOOSENESS, OF
PARTS.
○
○
-
-
SHOCK
490 m/s2 DURATION OF PULSE 11 ms AT
3
TIMES
1) NO ELECTRICAL DISCONTINUITY OF 1 μs.
2) NO DAMAGE, CRACK AND LOOSENESS, OF
PARTS.
FOR
6 DIRECTIONS.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 40 ℃, 90 TO 95 %, 96 h.
1) INSULATION RESISTANCE: 2 MΩMIN
(AT HIGH HUMIDITY).
(STEADY STATE)
2) INSULATION RESISTANCE: 20 MΩMIN
(AT DRY).
○
○
-
-
3) NO DAMAGE.CRACK AND LOOSENESS OF
PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE -15→ R/T → +60 → R/T ℃
TIME 30 → 10 TO 15 → 30 → 10 TO 15 min
UNDER 5 CYCLES.
1) INSULATION RESISTANCE: 1000 MΩMIN.
2) NO DAMAGE.CRACK AND LOOSENESS OF
PARTS.
CORROSION SALT MIST
DRY HEAT
EXPOSED IN 5 % SALT WATER SPRAY FOR 48 h.
NO HEAVY CORROSION.
○
○
-
-
EXPOSED AT +85 ℃ , 96 h.
NO DAMAGE,CRACK AND LOOSENESS OF
PARTS.
COLD
EXPOSED AT - 55 ℃ , 96 h.
NO DAMAGE,CRACK AND LOOSENESS OF
PARTS.
○
-
SEALING
EXPOSED AT A DEPTH OF OF – m FOR
h.
NO WATER PENETRATION INSIDE CONNECTOR.
-
-
-
-
AIRTIGHTNESS
APPLY AIR PRESSURE – Pa FOR – h TO INSIDE
NO ARI BUBBLES INSIDE CONNECTOR.
CONNECTOR.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KH.SHIINA
15.07.21
15.07.21
15.07.21
15.07.21
(1) CONTACT RESISTANCE INCLUDES BULX RESISTANCE OF USED WIRE.
TS.FURUYA
MK.OGURA
MK.OGURA
Unless otherwise specified, refer to JIS C 5402.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-102131-71-00
HR12-10LA8PS1065(71)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
CL112-3040-0-71
△
1/1
FORM HD0011-2-1