MODEL: HPV  
Space-saving Plug-in Signal Conditioners H-UNIT  
POWER INPUT  
DC Power  
R: 24 V DC  
P/I TRANSDUCER  
Functions & Features  
(Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)  
• Converting a standard pneumatic signal into a  
proportional DC output  
[2] OPTIONS (multiple selections)  
• High-density mounting  
Input  
blank: 0.2 – 1.0 kgf/cm  
/A1S: 19.6 – 98.1 kPa  
/A2S: 20 – 100 kPa  
/A3S: 20.7 – 103.4 kPa  
/A2: 0.2 – 1.0 bar  
2
Typical Applications  
• Converting a pneumatic system into a 4 – 20 mA for  
indicating and controlling in DCS system  
25 (.98)  
/A3: 3 – 15 psig  
H•UNIT  
HPV  
Pneumatic Connection  
blank: Rc 1/4"  
123  
(4.84)  
/P7: 1/4" NPT fitting  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
120  
(4.72)  
Connection  
mm (inch)  
Output & power input: M3.5 screw terminals;  
torque 0.8 N·m  
MODEL: HPV–[1]–R[2]  
Pneumatic: Rc 1/4" or 1/4" NPT female; torque ≤ 12 N·m  
Material  
Housing: Flame-resistant resin (black)  
Base socket: Die cast aluminium  
Screw terminals: Nickel-plated steel  
Isolation: Output to power  
ORDERING INFORMATION  
• Code number: HPV–[1]–R[2]  
Specify a code from below for each of [1] and [2].  
(e.g. HPV-A-R/A2S/P7)  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
• Special output range (For codes Z & 0)  
[1] OUTPUT  
Current  
INPUT SPECIFICATIONS  
Input  
A: 4 – 20 mA DC (Load resistance 750 Ω max.)  
B: 2 – 10 mA DC (Load resistance 1500 Ω max.)  
C: 1 – 5 mA DC (Load resistance 3000 Ω max.)  
D: 0 – 20 mA DC (Load resistance 750 Ω max.)  
E: 0 – 16 mA DC (Load resistance 900 Ω max.)  
F: 0 – 10 mA DC (Load resistance 1500 Ω max.)  
G: 0 – 1 mA DC (Load resistance 15 kΩ max.)  
Z: Specify current (See OUTPUT SPECIFICATIONS)  
Voltage  
19.6 – 98.1 kPa, 0.2 – 1.0 kgf/cm  
2
20 – 100 kPa, 0.2 – 1.0 bar  
20.7 – 103.4 kPa, 3 – 15 psig  
OUTPUT SPECIFICATIONS  
■ DC Current: 0 – 20 mA DC  
Minimum span: 1 mA  
Offset: Max. 1.5 times span  
1: 0 – 10 mV DC (Load resistance 10 kΩ min.)  
2: 0 – 100 mV DC (Load resistance 100 kΩ min.)  
3: 0 – 1 V DC (Load resistance 1000 Ω min.)  
4: 0 – 10 V DC (Load resistance 10 kΩ min.)  
5: 0 – 5 V DC (Load resistance 5000 Ω min.)  
6: 1 – 5 V DC (Load resistance 5000 Ω min.)  
0: Specify voltage (See OUTPUT SPECIFICATIONS)  
Load resistance: Output drive 15 V max.  
DC Voltage: 0 – 12 V DC  
Minimum span: 5 mV  
Offset: Max. 1.5 times span  
Load resistance: Output drive 1 mA max.; at ≥ 1 V  
INSTALLATION  
Current consumption: Approx. 60 mA  
Operating temperature: -5 to +55°C (23 to 131°F)  
HPV SPECIFICATIONS  
ES-3420 Rev.9 Page 1/3  
http://www.m-system.co.jp/  

与HPV-D-R/A3S相关器件

型号 品牌 获取价格 描述 数据表
HPV-D-R/P7 MSYSTEM

获取价格

Space-saving Plug-in Signal Conditioners H-UNIT
HPV-DV-10A EATON

获取价格

Single-pole, non-serviceable in-line PV fuse holder and fuse assembly
HPV-DV-10A COOPER

获取价格

Single-pole, non-serviceable in-line PV fuse holder and fuse assembly
HPV-DV-12A EATON

获取价格

HPV single-pole, non-serviceable in-line PV fuse holder and fuse assembly: 1-20 A, 1000 Vd
HPV-DV-12A COOPER

获取价格

Single-pole, non-serviceable in-line PV fuse holder and fuse assembly
HPV-DV-15A EATON

获取价格

HPV single-pole, non-serviceable in-line PV fuse holder and fuse assembly: 1-20 A, 1000 Vd
HPV-DV-15A COOPER

获取价格

Single-pole, non-serviceable in-line PV fuse holder and fuse assembly
HPV-DV-1A EATON

获取价格

HPV single-pole, non-serviceable in-line PV fuse holder and fuse assembly: 1-20 A, 1000 Vd
HPV-DV-1A COOPER

获取价格

Single-pole, non-serviceable in-line PV fuse holder and fuse assembly
HPV-DV-2.5A EATON

获取价格

HPV single-pole, non-serviceable in-line PV fuse holder and fuse assembly: 1-20 A, 1000 Vd