5秒后页面跳转
HPS10R-A3R-004 PDF预览

HPS10R-A3R-004

更新时间: 2024-11-06 05:36:27
品牌 Logo 应用领域
艾默生 - EMERSON-NETWORKPOWER /
页数 文件大小 规格书
5页 1391K
描述
HPS10/12/15 Series

HPS10R-A3R-004 数据手册

 浏览型号HPS10R-A3R-004的Datasheet PDF文件第2页浏览型号HPS10R-A3R-004的Datasheet PDF文件第3页浏览型号HPS10R-A3R-004的Datasheet PDF文件第4页浏览型号HPS10R-A3R-004的Datasheet PDF文件第5页 
1000-6000 Watts  
HPS10/12/15 Series  
Electrical Specs  
Input  
Input voltage  
Frequency  
85-264 VAC*  
47-440 Hz  
Inrush current  
Efficiency  
Power factor  
Turn-on time  
40 A peak max.  
85% typ @ full case load 230 VAC  
0.99 typical meets EN61000-3-2  
AC on 1.5 sec. typical, Inhibit /  
Enable 100 ms typical  
Special Features  
EMI filter standard  
Leakage current standard 2 mA max @ 264 VAC @ 60Hz  
CISPR 22 EN55022 Level “B”  
• Integrated OR-ing diode  
(per module)  
CISPR 22 EN55022 Level “B”  
20 ms minimum  
(independent of input VAC)  
>5 ms early warning min. before  
outputs lose regulation; Full cycle  
ride thru (50 Hz)  
Meets EN61000-3-2  
Meets EN60950  
• Remote Sense on Bulk output  
• Overload protection on all outputs  
• Active Inrush limiting  
Radiated EMI  
Holdup time  
• PFC to 0.99 typical EN61000-3-2  
• CISPR22, EN55022 Curve B  
conducted/radiated EMI  
AC OK  
• EN61000 immunity standards  
• Optional 48 W fan voltage (12 V or 24 V)  
• Standard 5 V at 5 A standby voltage (3.3V option)  
• No minimum load  
Harmonic distortion  
Isolation  
* see modules table on the next page  
• Overvoltage protection  
• Input OK signal and indicator LED  
• Inhibit/Enable  
• Remote Margin/Voltage Programming  
• Optional current monitor  
Output  
Margining  
±5% of nominal  
1%  
Overall reg  
• Optional AC Line discrimination  
• Output Good signal and indicator LED  
• Temp good signal and indicator LED  
• Optional single wire digital temp monitor  
• Optional module I2C interface  
• Optional Rack µController  
• Hot Plug  
Ripple  
1% of Vout Pk-Pk limited to 20 MHz  
2% with 25% load step  
To within 1% in <300 µsec  
105-120% of rated output current  
Protected for continuous short  
circuit. Recovery is automatic upon  
removal of short  
Dynamic response  
Recovery time  
Overcurrent protection  
Short circuit protection  
• N+1 Redundant Standard  
Overvoltage protection  
105-120% . Recycle AC input voltage  
to reset OVP circuit  
• Optional fan fail signal  
• Module present signal  
Reverse voltage  
protection  
• Optional short circut latch  
100% of rated output current  
Thermal protection  
Main and Aux disabled when internal  
Environmental & Safety  
Operating temperature: -10°C to +50°C ambient,  
derate output @ 2.5% per degree from 50°C to 70°C  
Shock/Vibration: Mil-Hdbk 810E  
temp exceeds safe operating range.  
Remote sense  
Single wire parallel  
Up to 0.5 V total drop  
Current share to within 10% of total  
rated current  
±5% of nominal  
Not required  
5 VDC @5A max. present whenever  
AC input is applied (3.3 V @ 5A  
optional)  
DC OK  
Minimum load  
Standby voltage  
Humidity: 95% non-condensing  
Storage temperature: -40°C to +85°C  
Temperature coefficient: 0.02% per °C  
Cooling: Internal DC fan  
MTBF (Calculated): 200 KHrs; 25°C, 200 VAC input,  
nominal O/P voltage, full load  
Global Inhibit/Enable  
Logic “0” standard logic “1” optional  
Safety:  
rd  
UL / CSA UL60950 3 Ed and CSA C22.2 60950  
TUV  
CB  
EN60950  
Certificate and report  
Mark  
CE  
152  
Technical Support: (888) 41-ASTEC or (407) 241-2752  
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662  
rev 08.25.04