1000-6000 Watts
HPS10/12/15 Series
Electrical Specs
Input
Input voltage
Frequency
85-264 VAC*
47-440 Hz
Inrush current
Efficiency
Power factor
Turn-on time
40 A peak max.
85% typ @ full case load 230 VAC
0.99 typical meets EN61000-3-2
AC on 1.5 sec. typical, Inhibit /
Enable 100 ms typical
Special Features
EMI filter standard
Leakage current standard 2 mA max @ 264 VAC @ 60Hz
CISPR 22 EN55022 Level “B”
• Integrated OR-ing diode
(per module)
CISPR 22 EN55022 Level “B”
20 ms minimum
(independent of input VAC)
>5 ms early warning min. before
outputs lose regulation; Full cycle
ride thru (50 Hz)
Meets EN61000-3-2
Meets EN60950
• Remote Sense on Bulk output
• Overload protection on all outputs
• Active Inrush limiting
Radiated EMI
Holdup time
• PFC to 0.99 typical EN61000-3-2
• CISPR22, EN55022 Curve B
conducted/radiated EMI
AC OK
• EN61000 immunity standards
• Optional 48 W fan voltage (12 V or 24 V)
• Standard 5 V at 5 A standby voltage (3.3V option)
• No minimum load
Harmonic distortion
Isolation
* see modules table on the next page
• Overvoltage protection
• Input OK signal and indicator LED
• Inhibit/Enable
• Remote Margin/Voltage Programming
• Optional current monitor
Output
Margining
±5% of nominal
1%
Overall reg
• Optional AC Line discrimination
• Output Good signal and indicator LED
• Temp good signal and indicator LED
• Optional single wire digital temp monitor
• Optional module I2C interface
• Optional Rack µController
• Hot Plug
Ripple
1% of Vout Pk-Pk limited to 20 MHz
2% with 25% load step
To within 1% in <300 µsec
105-120% of rated output current
Protected for continuous short
circuit. Recovery is automatic upon
removal of short
Dynamic response
Recovery time
Overcurrent protection
Short circuit protection
• N+1 Redundant Standard
Overvoltage protection
105-120% . Recycle AC input voltage
to reset OVP circuit
• Optional fan fail signal
• Module present signal
Reverse voltage
protection
• Optional short circut latch
100% of rated output current
Thermal protection
Main and Aux disabled when internal
Environmental & Safety
Operating temperature: -10°C to +50°C ambient,
derate output @ 2.5% per degree from 50°C to 70°C
Shock/Vibration: Mil-Hdbk 810E
temp exceeds safe operating range.
Remote sense
Single wire parallel
Up to 0.5 V total drop
Current share to within 10% of total
rated current
±5% of nominal
Not required
5 VDC @5A max. present whenever
AC input is applied (3.3 V @ 5A
optional)
DC OK
Minimum load
Standby voltage
Humidity: 95% non-condensing
Storage temperature: -40°C to +85°C
Temperature coefficient: 0.02% per °C
Cooling: Internal DC fan
MTBF (Calculated): 200 KHrs; 25°C, 200 VAC input,
nominal O/P voltage, full load
Global Inhibit/Enable
Logic “0” standard logic “1” optional
Safety:
rd
UL / CSA UL60950 3 Ed and CSA C22.2 60950
TUV
CB
EN60950
Certificate and report
Mark
CE
152
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662
rev 08.25.04