VDE
2c, 3c
10 AMP POWER RELAY
FEATURES
HP-RELAYS
25
.984
36
1.417
• Interchangeable with existing models
• Long life and high reliability
44.5
1.752
• High contact capacity up to 10 A 250 V AC
• Available with plug-in/solder and quick-connect terminals
mm inch
SPECIFICATIONS (at 20°C 68°F)
Contacts
Characteristics (at 60 Hz, 20°C 68°F)
Arrangement
2 Form C 3 Form C 4 Form C
15 mΩ
2 Form C 3 Form C 4 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Maximum operating speed
Initial insulation resistance*1
20 cpm
more than 100 MΩ at 500 V DC
Silver
alloy
Between open
contacts
1,000
Vrms
2,000
Vrms
1,000
Vrms
Contact material
Silver
Nominal switching
capacity
Breakdown
voltage*2
1,500
Vrms
2,000
Vrms
1,500
Vrms
Rating
10 A 250 V AC (resistive)
Between contact sets
Remarks
Between contact and
coil
1,500
Vrms
2,000
Vrms
1,500
Vrms
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "initial breakdown voltage" section
*2 Detection current; 10 mA
Approx.
15 ms
Operate time*3 (at nominal voltage)
Approx. 25 ms
Approx. 25 ms
*3 Excluding contact bounce time
*4 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*5 Half-wave pulse of sine wave: 6ms
Release time (without diode)*3
(at nominal voltage)
Approx.
15 ms
*6 Detection time: 10µs
*7 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
Temperature rise
Max. 65°C
98 m/s2 {10 G}
Functional*4
Destructive*5
Shock resistance
980 m/s2 {100 G}
58.8 m/s2 {6 G}, 10 to 55 Hz
at 1 mm double amplitude
117.6 m/s2 {12 G}, 10 to 55 Hz
at 2 mm double amplitude
Functional*6
Vibration resistance
Destructive
Conditions for opera-
Ambient
–50°C to +40°C
–58°F to +104°F
tion, transport and
temp.
storage*7
(Not freezing and
condensing at low
temperature)
Humidity
5 to 85% R.H.
Approx.
60g
Approx.
100g
Approx.
125g
Unit weight
2.12 oz
3.53 oz
4.41 oz
LIFE DATA
Contact rating and expected life For AC load type
Voltage
Load
125 V AC
250 V AC
Expected life
(min. operations)
Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4) Resistive (cos ϕ ] 1) Inductive (cos ϕ ] 0.4)
—
10 A
5 A
1A
—
7.5 A
10 A
7.5 A
3 A
7.5 A
5 A
2×105
5×105
1×106
2×106
1×107
Electrical
life
Current
3 A
2 A
0.7 A
0.6 A
0.4 A
Mechanical life
Note: When the electromagnet or exciting coil (Solenoid, etc.) is the load, the value of motor or lamp load is applicable.
411