120W Single Output Switching Power Supply
HLG-120H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
High efficiency up to 93.5%
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1~10Vdc or PWM signal or resistor)
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
5 years warranty (Note.10)
110
F
M
M
SELV
IP65 IP67
HLG-120H-12
A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable with 1~10Vdc or 10V PWM signal or resistor.
SPECIFICATION
HLG-120H-36
HLG-120H-42
MODEL
HLG-120H-12
HLG-120H-15
HLG-120H-20
HLG-120H-24
HLG-120H-30
HLG-120H-48
HLG-120H-54
36V
42V
DC VOLTAGE
12V
15V
20V
24V
30V
48V
54V
18 ~ 36V
3.4A
21 ~ 42V
2.9A
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
8A
10 ~ 20V
6A
12 ~ 24V
5A
15 ~ 30V
4A
24 ~ 48V
2.5A
27 ~ 54V
2.3A
RATED CURRENT
RATED POWER
10A
122.4W
200mVp-p
33 ~ 40V
121.8W
200mVp-p
38 ~ 46V
120W
120W
120W
150mVp-p
120W
120W
120W
124.2W
200mVp-p
49 ~ 58V
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
22 ~ 27V
200mVp-p
27 ~ 33V
200mVp-p
43 ~ 53V
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V 13.5 ~ 17V 17 ~ 22V
OUTPUT
Can be adjusted by internal potential meter or through output cable
CURRENT ADJ. RANGE
5 ~ 10A
VOLTAGE TOLERANCE Note.3 2.5%
1.7 ~ 3.4A
1.0%
1.4 ~ 2.9A
1.0%
4 ~ 8A
2.0%
0.5%
1.5%
3 ~ 6A
1.0%
0.5%
0.5%
2.5 ~ 5A
1.0%
2 ~ 4A
1.0%
0.5%
0.5%
1.2 ~ 2.5A
1.0%
1.1 ~ 2.3A
1.0%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
0.5%
2.0%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.8 2500ms, 50ms at full load 230VAC / 115VAC ; B type 2500ms, 200ms at 95% load 230VAC / 115VAC
12ms at full load 230VAC / 115VAC
Note.5 90 ~ 305VAC
127 ~ 431VDC
47 ~ 63Hz
PF 0.95/230VAC
PF 0.98/115VAC at full load and rated output voltage
PF 0.9 at 50 ~ 100% load
INPUT
EFFICIENCY (Typ.)
AC CURRENT
92%
93%
93%
93%
93.5%
93.5%
92%
93%
93%
1.4A / 115VAC
0.6A / 230VAC
0.55A / 277VAC
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
COLD START 75A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
OVER VOLTAGE
34 ~ 38V
41 ~ 46V
47 ~ 53V
54 ~ 60V
59 ~ 65V
14 ~ 17V
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
100 10 (RTH2)
18 ~ 21V
23 ~ 27V
28 ~ 34V
PROTECTION
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
0.03%/ (0 ~ 50
)
VIBRATION
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
EN61347-1, EN61347-2-13 independent IP65 or IP67 approved ; Design refer to UL60950-1, TUV EN60950-1
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
192.2Khrs min. MIL-HDBK-217F (25
220*68*38.8mm (L*W*H)
)
OTHERS
NOTE
DIMENSION
1.12Kg; 12pcs/14.4Kg/0.76CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A only.
7. Safety and EMC design refer to EN60598-1, CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
10. Refer to warranty statement.