APPLICABLE STANDARD
OPERATING
MIL-STD-348B
STORAGE
- 55゚C TO + 105゚C (95%RH MAX)
- 55゚C TO + 50゚C (95%RH MAX)
50Ω( 0 TO 40 GHz)
―――
TEMPERATURE RANGE
TEMPERATURE RANGE
CHARACTERISTIC
IMPEDANCE
RATING
――W
―――
POWER
APPLICABLE
CABLE
PECULIARITY
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
ACCORDING TO DRAWING.
X
X
-
-
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CENTER CONTACT
OUTER CONTACT
4
2
m MAX.
m MAX.
M MIN.
100 mA MAX (DC OR 1000 Hz).
X
X
X
X
X
X
X
X
1000
500 V DC.
INSULATION RESISTANCE
VOLTAGE PROOF
500 V AC FOR 1 min. CURRENT LEAKAGE 2mA MAX.
NO FLASHOVER OR BREAKDOWN.
VOLTAGE STANDING
WAVE RATIO
FREQUENCY 0.04 TO 40 GHz
VSWR
VSWR
VSWR
1.10
1.15
1.30
MAX. (0.04 to 18 GHz)
MAX. (18 to 26.5 GHz)
MAX. (26.5 to 40 GHz)
1
TEST METHOD IS Back to Back
X
-
-
FREQUENCY ---- TO ---- GHz
---
dB MAX.
INSERTION LOSS
-
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
INSERTION FORCE
EXTRACTION FORCE
INSERTION FORCE
EXTRACTION FORCE
---
0.4
---
---
N MAX.
N MIN.
N MAX.
N MIN.
-
X
-
X
0
-0.0025
EXTRACTION FORCES
Φ0.9195
BY STEEL GAUGE.
-
-
-
-
INSERTION AND
WITHDRAWAL FORCES
MECHANICAL OPERATION
MEASURED BY APPLICABLE CONNECTOR.
500 TIMES INSERTIONS AND EXTRACTIONS.
1)CONTACT RESISTANCE:
CENTER CONTACT
6 m MAX.CHANGE
4 m MAX.CHANGE
OUTER CONTACT
X
-
2)NO DAMAGE,CRACK AND LOOSENESS
OF PARTS.
FREQUENCY 10 TO 2000 Hz
VIBRATION
SHOCK
1)NO ELECTRICAL DISCONTINUITY OF
1 s.
2)NO DAMAGE,CRACK AND LOOSENESS
SINGLE AMPLITUDE 0.75 mm, 196 m/s2
X
X
-
-
-
AT 12 CYCLES FOR 3 DIRECTIONS.
1960 m/s2 DIRECTIONS OF PULSE 6 ms
AT 3 TIMES FOR 3 DIRECTIONS.
OF PARTS.
CABLE CLAMP
ROBUSTNESS
(AGAINST CABLE PULL)
APPLYING A PULL FORCE THE CABLE AXIALLY
AT --N MAX.
1)NO WITHDRAWAL AND BREAKAGE OF
CABLE.
-
2)NO BREAKAGE OF CLAMP.
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT -10 TO +65C, 90 TO 98
1)INSULATION RESISTANCE:
(AT HIGH HUMIDITY)
2)INSULATION RESISTANCE:
(AT DRY)
100 M MIN.
1000 M MIN.
TOTAL 10 CYCLES ( 240h )
X
-
3)NO DAMAGE,CRACK AND LOOSENESS
OF PARTS.
RAPID CHANGE
OF TEMPERATURE
TEMPERATURE -55 → --- → +105 → --- ℃
NO DAMAGE,CRACK AND LOOSENESS OF
PARTS.
TIME 30 → 3
UNDER 5 CYCLES.
→
30 → 3 min
X
X
-
-
EXPOSED IN 5% SALT WATER SPRAY FOR 48h.
DESCRIPTION OF REVISIONS
NO HEAVY CORROSION.
CORROSION SALT MIST
COUNT
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KY.SHIMIZU
TO.KATAYAMA
NK.OOSAWA
NK.OOSAWA
15.10.22
15.10.22
15.10.22
15.10.22
RoHS COMPLIANT
1
Note
Measurement state of Back to Back.
Port1
Port2
Unless otherwise specified, refer to MIL-STD-202.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
ELC-366760-11-00
DRAWING NO.
PART NO.
CODE NO.
SPECIFICATION SHEET
HK-R-SR2-1(11)
HIROSE ELECTRIC CO., LTD.
△
0
1/1
CL338-0003-0-11
FORM HD0011-2-1