Applicable standard
Operating
Storage
-55 °C to +125 °C ( 95 %RH Max.)
-55 °C to +125 °C ( 95 %RH Max.)
temperature range
temperature range
Characteristic
impedance
Applicable
cable
-- W
----
50 Ω( 0 to 40 GHz)
Rating Power
----
Peculiarity
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
According to drawing.
QT AT
CONSTRUCTION
General examination
Marking
Visually and by measuring instrument.
Confirmed visually.
X
X
X
X
ELECTRICAL CHARACTERISTICS
Contact resistance
100 mA Max.(DC or 1000 Hz)
Center contact 8 mΩ Max.
Outer contact 4 mΩ Max.
1000 MΩ Min.
X
X
X
X
X
X
X
X
Insulation resistance
Withstanding voltage
Voltage standing
wave ratio
500 V DC.
500 V AC for 1 min. current leakage 2 mA Max.
Frequency 0 to 18 GHz.
Frequency 18 to 26.5 GHz
Frequency 26.5 to 40 GHz.
Frequency 0 to 40 GHz.
No flashover or breakdown.
VSWR 1.1 Max.
VSWR 1.15 Max.
VSWR 1.2 Max.
0.03+0.03√f dB Max. f:GHz
X
X
X
X
Insertion loss
MECHANICAL CHARACTERISTICS
+0.005
Contact insertion and
extraction forces
Insertion and
φ 0.91
by steel gauge.
Insertion force
Extraction force 0.5 to 4.9 N
Insertion force --- N Max.
--- N Max.
-
X
-
X
0
Measured by applicable connector.
1000 times insertion and extractions.
-
-
-
-
extraction forces
Mechanical operation
Extraction force --- N Min.
1)Contact resistance:
Center contact 12 mΩ Max.
Outer contact 8 mΩ Max.
2)No damage, crack and looseness of parts.
X
-
Vibration
Shock
Frequency 10 to 2000 Hz single amplitude 0.75 mm, 1)No electrical discontinuity of 1 μs.
X
X
-
-
196 m/s2 at 10 cycles for 3 directions.
1960 m/s2 directions of pulse 6 ms
at 3 times for 6 directions.
2)No damage, crack and looseness of parts.
Cable clamp strength
(Against cable pull)
Using a pulling tester, pull the cable axially at a rate
N Min.
of
mm/min. and record the strength at which
-
-
the cable or connector breaks.
ENVIRONMENTAL CHARACTERISTICS
Damp heat
Exposed at -10 to +65 °C, 90 to 98 %
total 10 cycles.( 240 h)
1)Insulation resistance: 100 MΩ Min.
(at high humidity)
2) Insulation resistance: 1000 MΩ Min.
(at dry)
X
-
3)No damage, crack and looseness of parts.
No damage, crack and looseness of parts.
Rapid change of
temperature
Temperature
Time
-55 → - →+125 → - °C
X
X
30 → 3
→ 30
→
3 min.
-
-
Under 5 cycles.
Exposed in 5 % salt water spray for 48 h.
Corrosion salt mist
Count
Electrical characteristic shall be met.
Description of revisions
Designed
Checked
Date
0
△
TO.KATAYAMA
KY.SHIMIZU
18.05.10
18.05.10
18.05.10
18.05.10
Remark
Approved
Checked
Designed
Drawn
TK.SAWAGUCHI
TK.SAWAGUCHI
Unless otherwise specified, refer to IEC 60512.
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
Drawing No.
Part No.
ELC-382712-00-00
HK-PA-JJ
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
Code No.
CL338-0112-0-00
FORM HD0011-2-1