H HiTRON
Universal AC Input Harmonic Correction AC-DC 6U Pentad Output
1000 Watts VPX Switching Power Supplies HAV1000 Series
Features
ꢀ
ꢀ
ꢀ
VITA 62 Compliant 6U 8HP or 10HP
VPX Power Supply
Wide Operating Temperature Range of
-40°C to +85 °C
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Internal Or-Ing Diodes for N+1 Redundancy
Active Current Sharing
EMI meet EN 55032 / Class A
PMBus Interface for Status & Control
Using 125°C Long Life Solid Capacitors
Specification
Input
General
Input Voltage
Input Frequency
Input Current
Typical 90-264VAC
47-63Hz
7.3A at 115VAC
Efficiency
Typical 89% at 230VAC
67-100KHz
Switching Frequency
Dielectric Withstand
Circuit Topology
Transient Response
Meet IEC60950-1 regulation
ZVS Half-bridge circuit
Peak transient < 600 &
recovers within 3mS after
25% load-change
Available
5.2A at 230VAC
Inrush Current
37.2A(peak) at 230VAC
10Arms at 230VAC
Typical 0.975 at 230VAC
Tyco 6450843-6
Power Factor
Input Connector
Earth Leakage Current Typical 1.1mA at 230VAC
Remote ON/OFF
Power Fail Signal
Available
No-load Power
Typical 11.8Watt at 115/230VAC Power OK Signal
Available
DC OK Signal
Available
Output
Output Connector
Line Regulation
Load Regulation
Tyco 6450843-6
Typical 0.5%
V1/V2/V3 typical ±1.5%
V4/V5 typical ±5%
N+1 Redundancy
Power Density
PMBus
internal OR-ing diodes
5.7-8.3Watts/ Cubic Inch
Built-in
Conformal Coating
Available
Total Regulation
V1/V2/V3 typical ±3%
Environmental
Operating Temperature
Storage Temperature
Cooling
V4/V5 typical ±5%
-40 °C to +85 °C with de-rating
-45°C to +90 °C
800LFM moving air
Noise & Ripple
Remote Sense
Adjustability
Typical 1.5% peak to peak
Available at V1,V2 & V3
Available at V1,V2 & V3
Available at V1, V2 & V3
Operating : 5-90 % (non-condensing)
Storage: 0-95% (non-condensing)
Humidity
Current Sharing
Protection
Over Voltage
Over Current
Over Load
Safety/EMC
Built-in at all outputs
Built-in
Emissions
(conducted)
EN55032 / FCC Class A
IEC61000-3-2
IEC 60950-1 Class I
Harmonic Current
Typical 110-150% maximum load Safety Standard
fully protected against output
Installed NTC and thermostat
6.2-7.3mS at 115VAC
CE Standard
Vibration
Meet Level 3 Criteria A
Six degree-of-freedom random
10Hz-150Hz, 5G
Over Temperature
Hold-up Time
2.3-2.8mS at 230VAC
Notes:
(1) All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2) Due to requests in market and advances in technology, specifications subject to change without notification.
(3) A warm-up time 10 minutes is required after cold start at temperature from -40°C to +0°C.
(4) Tantalum capacitors connected to system is suggested for bettering Ripple & Noise against operating temperature from -40°C to +0°C.
(5) 125°C OS-CON Long-life Solid capacitors are installed in secondary circuits.
Version
L edited on Dec. 4, 2018