H HiTRON
ON-BOARD UNIVERSAL INPUT AC-DC ENCAPSULATED MODULAR
POWER SUPPLIES 10 WATTS SINGLE & DUAL OUTPUT
HAM10S & HAM10D SERIES
FEATURES:
ꢀ
ON-BOARD AC/DC MODULAR
POWER SUPPLIES
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
UNIVERSALAC INPUT RANGE
COMPACT IN SIZE
MEET UNIVERSAL SAFETY STANDARDS
EMI MEET CISPR PUB.22 / FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 10 Watts typical.
Output Indicator: LED.
Input Voltage: 90-264Vac typical. (or 110-340Vdc).
Input Frequency: 47-63 Hz. (50/60Hz.Nom.) or DC.
Input Current: 0.3A @115Vac./ 0.13A @ 230Vac.
Inrush Current: 32.5A peak @230Vac.
Input Fuse: Use external fuse. 1.0A/250Vac for
primary fuse is suggested.
Line Regulation: Various with output voltage.
HAM10S ±0.1% typical.
HAM10D ±0.2% typical.
Load Regulation: Various with output voltage.
HAM10S ±1.0% typical.
Dielectric Withstand: Meet IEC950.
3,000Vac-Output/Input.
HAM10D ±2.0% typical.
Noise & ripple: 1.0% typical peak to peak.
OVP: Built-in on main output.
1,500Vac-Input/GND.
500Vac-Output/GND.
EMI: Meet CISPR PUB.22/ FCC Class B.
Hold-up time: 20mS @115Vac, 80mS @230Vac.
Earth Leakage: Less than 3.5mA @230Vac.
Adjustability: From -10% of main output till OVP.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Operating Temperature: -10 to +70°C range.
Efficiency: 67-79% typical (Various with output voltage).
Switching Frequency: 75K Hz.
-10°C to +50°C full load without derating.
From +50°C, derating linearly to half load @+70°C.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Typical peak deviation 250mV,
Recovery time < 3mS for a 25% load change.
Case: Impact resistant thermo-plastic enclosure.
Weight: 120g (4.23 Oz).
(Refer to Derating Chart.)
Storage Temperature: -20°C to +85°C.
Temperature Coefficient: ± 0.02% /°C.
Humidity: Up to 95%RH, Non-condensing.
Cooling: Convection cooling for +50°C @ full load.
At least 100LFM moving air is recommended
for full load > +50°C in a confined area.
Commercial Grade only.
Power Density: 2.51 Watts. / Cubic inch.
Safety Standard: EN60950/ UL1950 Class I.
MTBF: 100,000 hours. Mil Std 217, 25°C.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load Regulation measured from Full-Load (F-L) to Half-Load (H-L) at nominal input and others loaded at half load.
Due to requests in market and advances in technology, specifications subject to change without notice.
-3-