1.27mm Pitch Two-Piece Connectors
HIF6 Series
Connector in combination with the HIF6 series connection type
●HIF3B Series ●HIF2 Series
(MIL-C-83503)
(Board direct mount type)
2
1
●HIF5 Series
●FD Series
(Card edge type)
(D sub-ribbon connector)
■Features
1. Product Variation
The connection method is available with the board to
board type and insulation displacement type.
Fig.1 (For further information, refer to catalog page B86.)
2. Broad applications
HIF2E, HIF3B and HIF5 can be combined one other,
because the 1.27mm pitch flat cable is used. (Fig.1)
3. Applicable Cables
The applicable cable is a (UL2651) 28 AWG flat cable
(7cores: 0.127mm, outer jacket diameter: 0.8 to1.0mm)
4. Mis-insertion Preventive Structure
The mis-insertion preventive guide prevents mis-
insertion.
■Product Specifications
Current rating : 0.5A
Operating Temperature Range : -55 to +85 ç (Note 1) Storage Temperature Range : -10 to +60ç (Note 2)
Rating
Voltage rating : 125V AC
Operating Humidity Range : 40 to 80%
Operating Humidity Range : 40 to 70% (Note 2)
Item
Specification
Condition
1.Insulation Resistance
2.Withstanding Voltage
3.Contact Resistance
4.Vibration
250V DC
1000MΩ min.
300V AC/1 minute.
No flashover or insulation breakdown.
30mΩ max.
0.1A
Frequency : 10 to 55 Hz, single amplitude of 0.75 mm, 2 hours in each of the 3 directions.
96 hours at temperature of 40ç and humidity of 90% to 95%
No electrical discontinuity of 1μs or more
Insulation resistance : 1000MΩ min.
5.Humidity (Steady state)
(-65ç : 30 minutes→15 to 35ç : 5 minutes max.→
125ç : 30 minutes→15 to 35ç : 5 minutes max.) 5 cycles
6.Temperature Cycle
No damage, cracks, or parts looseness.
Contact resistance : 30mΩ max.
7.Durability (Mating/un-mating)
8.Resistance to Soldering heat
500 cycles
Solder bath : 260ç for 10 seconds
Manual soldering : 360ç for 5 seconds
No deformation of components affecting performance.
Note 1 : Includes temperature rise caused by current flow.
Note 2 : The term "storage" refers to products stored for long period of time prior to mounting and use. Operating Temperature Range and
Humidity range covers non conducting condition of installed connectors in storage, shipment or during transportation.
Note 3 : Please note that there is a risk of deforming the lock when an excessive load is applied to the inside.
B69