5秒后页面跳转
HFD17/18-ZF-3N PDF预览

HFD17/18-ZF-3N

更新时间: 2024-09-23 02:48:23
品牌 Logo 应用领域
HONGFA /
页数 文件大小 规格书
3页 609K
描述
SUBMINIATURE SIGNAL RELAY

HFD17/18-ZF-3N 数据手册

 浏览型号HFD17/18-ZF-3N的Datasheet PDF文件第2页浏览型号HFD17/18-ZF-3N的Datasheet PDF文件第3页 
SUBMINIATURE SIGNAL RELAY  
HFD17  
Features  
8A switching capability  
UL insulation system: Class F available  
Plastic sealed and flux proofed types available  
Standard PCB layout  
File No.: E133481  
Product in accordance to IEC 60335-1 available  
File No.:R50431434  
RoHS compliant  
COIL  
CONTACT DATA  
Contact arrangement  
1C  
Coil power  
200mW;  
100m max.  
(AgNi gold-plated specifications:  
0.1A 6VDC, AgNi non gold-plated specifications  
and AgSnO2:1A 6VDC)  
Contact resistance1)  
Contact material  
COIL DATA  
AgNi, AgSnO2  
at 23  
Contact rating  
(Res. load)  
3A 30VDC  
3A 250VAC  
Pick-up Drop-out  
Coil Resistance  
x (1 10%)  
Max.  
Voltage2)  
VDC  
Nominal  
Voltage  
VDC  
Voltage Voltage  
VDC1)  
max.  
VDC1)  
min.  
Max. switching voltage  
Max. switching current  
Max. switching power  
Min. applicable load  
250VAC / 220VDC  
8A  
Standard  
1.80  
2.25  
3.38  
3.75  
4.5  
2.4  
3
0.24  
0.3  
0.45  
0.5  
0.6  
0.9  
1.2  
1.8  
2.4  
3.12  
3.90  
5.85  
6.50  
6.63  
11.7  
15.6  
23.4  
31.2  
28.8  
45.0  
101.3  
120  
750VA / 90W  
5V 1mA(Suitable for AgNi gold-plated specifications)  
1 x 107OPS  
1x105OPS(AgNi85C1son9soffNO.  
4.5  
5
Mechanical endurance  
o
Electrical endurance  
HFD17:3A 125VAC HFD17-1:1A 125VAC)  
6
180  
Notes: 1) The data shown above are initial values.  
2)Min. applicable load is reference value. Please perform the  
confirmation test with the actual load before production since  
reference value may change according to switching frequencies,  
environmental conditions and expected contact resistance and  
reliability.  
6.75  
9.00  
13.5  
18.0  
9
400  
12  
18  
24  
700  
1620  
2800  
CHARACTERISTICS  
Insulation resistance  
1000M (at 500VDC)  
750VAC 1min  
Notes: 1) The data shown above are initial values.  
2)Maximum voltage refers to the maximum voltage which relay  
coil could endure in a short period of time.  
between open contacts  
between coil & contacts  
Dielectric  
strength  
1500VAC 1min  
SAFETY APPROVAL RATINGS  
Surge withstand voltage  
between open contacts(10/160 µ s)  
between coil & contacts(2/10 µ s)  
1500V(FCC part 68)  
2000V(Telecordia)  
HFD17-1  
HFD17  
3A 125VAC,85oC  
3A 250VAC,Room temp  
3A 30VDC,85oC  
1A 125VAC,85oC  
1A 250VAC,Room temp  
1A 30VDC,85oC  
Operate time (at rated voltage.)  
Release time (at rated voltage.)  
Ambient temperature  
Humidity  
5ms max.  
5ms max.  
AgNi  
UL/CUL  
3A 250VAC,85oC  
3A 30VDC,85oC  
1A 250VAC,85oC  
1A 30VDC,85oC  
-40 to 85  
5% to 85% RH  
147m/s2  
AgSnO2  
TV-1 125VAC,Room temp  
Functional  
Shock resistance  
3A 125VAC,85oC  
3A 250VAC,Room temp  
3A 30VDC,85oC  
1A 250VAC,85oC  
980m/s2  
Destructive  
1A 250VAC,Room temp  
1A 30VDC,85oC  
AgNi  
Functional  
10Hz to 55Hz 2.5mm DA  
3A 250VAC,85oC  
Vibration resistance  
Destructive  
TÜV  
1A 250VAC,85oC  
10Hz to 55Hz 5mm DA  
DIP  
3A 30VDC,85oC  
1A 30VDC,85oC  
AgSnO2  
Termination  
Unit weight  
Construction  
1(1) 250VAC,Room temp 1(1) 250VAC,Room temp  
Approx. 4g  
Plastic sealed  
Flux proofed  
Notes: 1)Only typical loads are listed above. Other load specifications  
can be available upon request.  
Notes: 1) The data shown above are initial values.  
2) UL insulation system: Class F.  
HONGFA RELAY  
2020 Rev. 1.00  
ISO9001, ISO/TS16949 , ISO14001, OHSAS18001, IECQ QC 080000 CERTIFIED  
48