5秒后页面跳转
HF161F-W PDF预览

HF161F-W

更新时间: 2024-09-23 02:55:27
品牌 Logo 应用领域
HONGFA /
页数 文件大小 规格书
3页 590K
描述
SOLAR RELAY

HF161F-W 数据手册

 浏览型号HF161F-W的Datasheet PDF文件第2页浏览型号HF161F-W的Datasheet PDF文件第3页 
HF161F-W  
SOLAR RELAY  
Features  
31A switching capacity  
Applicable to inverter used for photovoltaic power  
generation systems  
File No.:E134517  
Ideal for UPS  
1.5mm contact gap (compliant to European Photovoltaic  
Standard VDE0126)  
V
D E  
1.8mm contact gap (compliant to IEC 62109-2-2011)  
The clearance distance between contact and coil is bigger  
than 6.4mm, the creepage distance is bigger than 8mm.  
(special code 477:7.5mm)  
File No.:40031410  
Low coil holding voltage contributes to saving energy of  
equipment.  
File No.:CQC10002050943  
CQC18002203499  
UL insulation system: Class F  
RoHS compliant  
CONTACT DATA  
CHARACTERISTICS  
Insulation resistance  
1.8mm  
1A  
2.0mm  
1000M (at 500VDC)  
4500VAC 1min  
2500VAC 1min  
10kV (1.2/50µs)  
20ms max.  
Contact gap  
1.5mm  
2.3mm  
Between coil & contacts  
Contact arrangement  
Dielectric  
strength  
1)  
Between open contacts  
Contact resistance  
100m (1A 6VDC)  
Surge voltage (between coil & contacts)  
Operate time (at rated. volt.)  
Release time (at rated. volt.)  
Contact material  
Contact rating  
AgSnO2  
Resistive:  
Resistive:  
Resistive:  
26A 250VAC  
Inductive:  
31A 250VAC  
(cosø=0.8)  
0.1s:10s  
26A 250VAC  
26A 250VAC  
10ms max.  
Resistive:  
26A 250VAC  
Inductive:  
Inductive:  
33A 250VAC  
31A 250VAC  
95K max. (Contact load current 31A,  
rated voltage excitation, at 60oC)  
(cosø=0.8)  
(cosø=0.8)  
Temperature rise  
(at rated. volt.)  
0.1s:10s  
0.1s:10s  
Max. switching voltage  
Max. switching current  
277VAC  
70K max. (Contact load current 31A,  
80% of rated voltage excitation, at 85oC)  
33A  
31A  
26A  
31A  
196m/s2  
980m/s2  
Functional  
Destructive  
Shock  
resistance  
Max. switching power  
Mechanical endurance  
7750VA 8250VA  
7750VA  
7202VA  
6
5
1 x 10 OPS 1 x 105OPS  
5
1 x 10 OPS 1 x 10 OPS  
10Hz to 55Hz 1.5mm DA  
Vibration resistance  
HT type:  
HT type:  
HT type:  
3 x 104OPS  
(26A 250VAC  
Resistive  
HT type:  
3 x 104OPS  
(26A 250VAC  
Resistive  
Room temp.  
1.5s on 1.5s off)  
3 x 104OPS  
3 x 104OPS  
-40oC to 85oC  
(Apply holding voltage to coil, which  
is 45% to 80% that of rated voltage)  
(26A 250VAC (26A 250VAC  
Electrical endurance  
Resistive  
75  
Resistive  
75  
Ambient temperature  
75  
1.5s on 1.5s off) 1.5s on 1.5s off)  
1.5s on 1.5s off)  
Notes: 1)The data shown above are initial values.  
Humidity  
5% to 85% RH  
PCB  
Termination  
Unit weight  
Construction  
COIL  
Approx. 21g  
Flux proofed  
Coil power  
Approx. 1.4W  
35% to 120%UN (at 23  
45% to 80%UN (at 85  
)
)
Holding voltage  
Notes: The data shown above are initial values.  
Notes: 1)The coil holding voltage is the voltage of coil after being applied  
rated voltage for 100ms  
SAFETY APPROVAL RATINGS  
2)The relay col does not allow applied more than maximum of  
holding voltage values for a long time (Eg: 120% Un at 23  
80% Un at 85 ) , prevent overheating burned.  
;
26A 277VAC at 75  
AgSnO2  
UL/CUL  
at 23  
COIL DATA  
22A 277VAC at 85  
Pick-up Drop-out  
Voltage Voltage  
Max.  
Voltage  
VDC *  
Nominal  
Voltage  
VDC  
Coil  
Resistance  
26A 277VAC at 75  
22A 277VAC at 85  
31A 250VAC cosØ =0.8 0.1s:10s  
33A 250VAC cosØ =0.8 0.1s:10s (477)  
2)  
VDC  
VDC  
min.  
VDE  
AgSnO2  
1)  
1)  
max.  
9
12  
18  
24  
6.3  
0.9  
10.8  
14.4  
21.6  
28.8  
58 x (1 10%)  
103 x (1 10%)  
230 x (1 10%)  
410 x (1 10%)  
Notes: 1) All values unspecified are at room temperature.  
2) Only typical loads are listed above. Other load specifications  
can be available upon request.  
8.4  
1.2  
1.8  
2.4  
12.6  
16.8  
Notes:1)The data shown above are initial values.  
2)*Maximum voltage refers to the maximum voltage which relay  
coil could endure in a short period of time.  
HONGFA RELAY  
ISO9001ISO/TS16949ISO14001OHSAS18001IECQ QC 080000 CERTIFIED  
2019 Rev. 1.00  
285