HIGH EFFICIENT
RECTIFIER DIODES
HER201 - HER208
PRV : 50 - 1000 Volts
Io : 2.0 Amperes
D2
FEATURES :
* High current capability
* High surge current capability
* High reliability
1.00 (25.4)
0.161 (4.1)
MIN.
0.154 (3.9)
* Low reverse current
* Low forward voltage drop
* Fast switching for high efficiency
0.284 (7.2)
0.268 (6.8)
1.00 (25.4)
MIN.
MECHANICAL DATA :
* Case : D2 Molded plastic
0.034 (0.86)
0.028 (0.71)
* Epoxy : UL94V-O rate flame retardant
* Lead : Axial lead solderable per MIL-STD-202,
Method 208 guaranteed
* Polarity : Color band denotes cathode end
* Mounting position : Any
Dimensions in inches and ( millimeters )
* Weight : 0.465 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating at 25 C ambient temperature unless otherwise specified.
°
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
HER HER HER HER HER HER HER HER
RATING
SYMBOL
UNIT
201
202
203
204
205
206
207
800 1000
560 700
208
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
VRRM
VRMS
VDC
50
100
200
300
400
600
V
V
V
35
50
70
140
200
210
300
280
400
420
600
Maximum DC Blocking Voltage
100
800 1000
Maximum Average Forward Current
IF(AV)
2.0
75
A
0.375"(9.5mm) Lead Length
Ta = 55 °C
Maximum Peak Forward Surge Current,
8.3ms Single half sine wave superimposed
on rated load (JEDEC Method)
IFSM
A
Maximum Forward Voltage at IF = 2.0 A
VF
IR
1.1
50
1.7
75
V
10
50
Maximum DC Reverse Current
at Rated DC Blocking Voltage
Ta = 25 °C
Ta = 100 °C
mA
mA
ns
IR(H)
Trr
Maximum Reverse Recovery Time ( Note 1 )
Typical Junction Capacitance ( Note 2 )
Junction Temperature Range
CJ
TJ
50
pf
°C
°C
- 65 to + 150
- 65 to + 150
Storage Temperature Range
TSTG
Notes :
( 1 ) Reverse Recovery Test Conditions : IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A.
( 2 ) Measured at 1.0 MHz and applied reverse voltage of 4.0 VDC
Page 1 of 2
Rev. 01 : April 2, 2002