VDE
TV-15, 30 AMP (1 Form A)
Power Relay
HE RELAYS
50
1.969
FEATURES
• High contact capacity with superior inrush current characteristics;
33
1.299
1 Form A
30 A 277 V AC 25 A 277 V AC
TV-15 TV-10
2 Form A
35.8
1.409
Rating
TV rating
• Excellent high heat-resistance;
• High dielectric strength: 10,000 V surge Conforming to VDE0806
(Insulation gap: 8 mm .315 inch) VDE,TÜV also approved
mm inch
SPECIFICATIONS
Contacts
Characteristics
Type
DC coil type
AC coil type
DC coil type
AC coil type
Arrangement
Contact material
1a
2a
1a
2a
Maximum operating speed
Initial insulation resistance*1
20 cpm
Silver alloy
Min. 1,000 MΩ at 500 V DC
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Between open contacts
2,000 Vrms for 1 min.
100 mΩ
Initial
Between contacts and
breakdown coil
5,000 Vrms for 1 min.
4,000 Vrms for 1 min.
Min. 10,000 V
30 A
277 V
AC
25 A
277 V
AC
30 A
277 V
AC
25 A
277 V
AC
Nominal
switching capacity
voltage*2
Between contact sets
(2a)
Max. switching
8,310
VA
6,925
VA
8,310
VA
6,925
VA
Surge voltage between coil
and contact*3
Operate time*4
(at nominal voltage)
Release time*4
Rating
power
(resistive)
Max. switching
277 V AC, 30 V DC
25 A 30 A
Approx. 20 ms
voltage
Max. switching
current
30 A
25 A
Approx. 5 ms Approx. 20 ms
(at nominal voltage)
Mechanical
(at 180 cpm)
107
5×106
Temperature rise, max.
(resistive load)(at 55°C)
Expected
life (min.
operations)
60°C
65°C
Electrical
(at 20 cpm)
105 (1a: 30 A 277 V AC, 2a: 25 A 277 V AC)
Functional*5
Destructive*6
98 m/s2 {10 G}
980 m/s2 {100 G}
2×105 (1a: 30 A 250 V AC, 2a: 20 A 250 V AC)
Shock resistance
Coil (at 20°C 68°F)
10 to 55 Hz
at double amplitude of 1 mm
Functional*7
DC coil type
1.92 W
AC coil type
Vibration resistance
10 to 55 Hz
at double amplitude of 1.5 mm
Nominal operating power
See Coil data (next page)
Destructive
Remarks
Conditions for opera-
tion, transport and
storage*8 (Not freezing
and condensing at low
temperature)
Ambient
temp.
–50°C to +55°C
–58°F to +131°F
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "initial breakdown voltage" section
*2 Detection current: 10 mA
Humidity
5 to 85% R.H.
86 to 106 kPa
*3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981
*4 Excluding contact bounce time
Air pressure
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
Approx. 90 g 3.17 oz
(Plug-in type)
Unit weight
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL
ORDERING INFORMATION
APPLICATIONS
HE
1a
N
S
DC12
V
1. Home appliances
• Air conditioners
• Microwave ovens
• TV sets
• Heaters
• Stereo
2. Office equipment
• Copiers
• Vending machines
Contact arrangement
Pick-up voltage
Terminals
Coil voltage
1a: 1 Form A
2a: 2 Form A
N: 70% of nominal
voltage
Nil: Plug-in terminal type
S: Screw terminal type
SW: Screw terminal type
(wide pitch)
Q: NEMA terminal type
P: PC board terminal type*
DC: 6, 12, 24, 48,
110 V
AC: 12, 24, 48,
120, 240 V
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
* PC board terminal are available only for 1 Form A type of DC coil voltage.
UL/CSA, TÜV approved type is standard.