H HiTRON
16.6-160VDC Input Range DC-DC Converter Single Output
100 Watts Railway Switching Power Supplies HDR100-110J Series
Features
ꢀ
ꢀ
ꢀ
ꢀ
100W Metal Box Format
16.6-160VDC 10:1 Wide Input Range
Design to Meet EN50155 Railway Standard
Wide Operating Temperature Range of
-40°C To +85 °C
ꢀ
ꢀ
ꢀ
Free Air Convection
Using 125°C Long Life Solid Capacitors
CE Marking Level 3 Compliance
Specification
Input
General
Input Voltage
16.6-160VDC, nominal 110VDC
4.65A at 24VDC/1.0A at 110VDC
0.08A at 24VDC/0.03A at 110VDC
Installed
Efficiency
Typical 86.6% at 16.6VDC
Typical 90.5% at 48 VDC
Typical 90.6% at 110 VDC
110KHz at nominal I/P 110VDC
I/P-O/P: 3000VAC
Input Current
(F-L)
(no-laod)
Soft Star
Switching Frequency
Dielectric Withstand
Inrush Current
Peak 27A at nominal 110VDC
V-H or M-T MA412-500M2B
Input Connector
I/P-GND:1500VAC
O/P-GND:1000VAC
Output
Output Connector
Line Regulation
Load Regulation
Total Regulation
Noise & Ripple
Adjustability
M-T MA412-500M2B
Typical 0.2%
Circuit Topology
Resonant ZVS & Fix-Flyback circuit
Peak transient < 300mV & recovers
within 3mS for 25% load-change
3.75Watts/Cubic Inch
Transient Response
Typical ±1%
Typical ±2%
Power Density
Typical 1% Peak-Peak
Factory Set
Environmental
Operating Temperature
Storage Temperature
Cooling
-40 °C to +85 °C with de-rating
-45°C to +90°C
Output Trim
Available
Convection-cooled
Protection
Over Voltage
Over Current
Over Load
Built-in
Safety/EMC
Emissions (conducted)
Safety Standard
CE Standard
Installed
CISPR EN55022 Class B
IEC60950-1 Class I
Typical 130% maximum load
fully protected against output
overload or short circuit
Thermostat
Meet Level 3 Criteria A
Six degree-of-freedom random
10Hz-150Hz, 10G
Vibration
Over Temperature
Input-Under &
Over-Voltage
Installed
Radiated Susceptibility
Surge
EN61000-4-3 Level X (20V/m)
EN61000-4-5 Level 3, L-L 2KV,L-G 2KV
Input Reverse Voltage Installed
Conducted Disturbance
EN61000-4-6 Level X (20V/m)
Conformal Coating
Available
Notes:
(1) All measurement are at nominal input, full load and +25°C unless otherwise specifications.
(2) Due to requests in market and advances in technology, specifications subject to change without notification.
(3) A warm-up time 10 minutes is required after cold start at temperature from -40°C to +0°C.
(4) 125°C OS-CON Long-life Solid capacitors are installed in secondary circuits.
Version
A edited on July 22, 2016
-1-