30W-40W
DC-DC CONVERTERS
✔ Single and Triple Output Models
✔ Wide Input Ranges
✔ 5V, 12V, 15V Outputs
✔ Pi Input Filters—Built-in EMI Suppression
✔ UL/CSA/VDE/EN Safety Standards
✔ 850-1500V Input/Output Isolation
✔ Short-Circuit/Over-Voltage Protection
✔ Remote Load Sensing
✔ Remote Shutdown/Output Adjustment
✔ 3”✕ 3” Six-Sided Metal Case
✔ 2-Year Warranty
✔ 700,000-Hour Minimum MTBF
Nominal
Input
Max.
CHARACTERISTICS
Input Voltage
DC
Output Output Line/
Min.Nom.Max. Current Output Current Voltage Load Effi-
EMI Suppression..........................Pi input filter, standard.
Base-Plate Temperature...............Operating temperature of +100°C,
max.with built-in thermal shutdown.
Model
(V) (V) (V)
(A) Output(V)
(A) Tolerance Reg. ciency
DC-DC 30W Singles
Isolation Voltage...........................D-input models: 1500V, input to output,
HD1-30-5A
HD1-30-5B
HD1-30-5D
9.0 12 25
18 24 36
36 48 75
3.16 V1 5.0
1.52 V1 5.0
0.75 V1 5.0
6.00
6.00
6.00
1.0% 0.3% 79%
1.0% 0.3% 82%
1.0% 0.3% 83%
for one minute. A- and B-input models:
850V, input to output, for one minute.
Output Adjustment........................Primary output adjustable 10%.
Continuous Output Power............HD1-30 and HD3-30 total output
power should not exceed 30W. HD1-
HD1-30-12A 9.0 12 25
HD1-30-12B 18 24 36
HD1-30-12D 36 48 75
3.09 V1 12
1.51 V1 12
0.75 V1 12
2.50
2.50
2.50
1.0% 0.3% 81%
1.0% 0.3% 83%
1.0% 0.3% 83%
40 and HD3-40 total output power
should not exceed 40W. Maximum
output current for individual outputs of
HD1-30-15A 9.0 12 25
HD1-30-15B 18 24 36
HD1-30-15D 36 48 75
3.01 V1 15
1.51 V1 15
0.73 V1 15
2.00
2.00
2.00
1.0% 0.3% 83%
1.0% 0.3% 83%
1.0% 0.3% 86%
triple output models appear in the rat-
ings table.
Minimum Load Requirement........Single output models, no minimum.
DC-DC 30W Triples†
Triple output models, 150 mA, mini-
mum on 5V output, 50 mA, minimum,
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 78%
2.5% 6.0%
on auxiliary outputs.
HD3-30-1A
HD3-30-1B
HD3-30-1D
HD3-30-2A
HD3-30-2B
HD3-30-2D
9.0 12 25
18 24 36
36 48 75
9.0 12 25
18 24 36
36 48 75
3.21 V2 +12 0.50
V3 - 12 0.50
Output Noise and Ripple..............5V output, 50 mVpp, maximum. 12V
and 15V outputs, 75 mVpp, maxi-
mum. (See Note 2.)
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 81%
2.5% 6.0%
Short-Circuit Protection ................Cycle-by-cycle current limiting.
Over-Voltage Protection ...............V1 output only: 125% of rated output,
typical. Single output models with 5V
1.54 V2 +12 0.50
V3 - 12 0.50
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 82%
2.5% 6.0%
outputs and all triple output models
0.76 V2 +12 0.50
V3 - 12 0.50
have latching OVP; RESET = 0V. All
other models are diode protected.
Under-Voltage Lockout.................Nom. Input
Off (Typ.) On (Typ.)
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 78%
2.5% 7.0%
3.21 V2 +15 0.40
V3 - 15 0.40
12V
24V
48V
7.5V
16.5V
34.0V
8.5V
17.5V
35.5V
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 81%
2.5% 7.0%
Transient Response .....................200 µs recovery after half-load to full load
step change to within 1% of the regulation
band with no more than 5% deviation.
Frequency of Operation ...............300 kHz.
Remote Shutdown........................CMOS and open-collector TTL com-
patible: ON = 2.4V to VIN(MAX); OFF
= 0.8V or less. Logic reference is -VIN.
Temperature Range......................-40°C to +85°C (ambient). See
Package Power De-Rating graph.
1.54 V2 +15 0.40
V3 - 15 0.40
V1 5.0
6.00
1.0% 0.3%
2.5% 5.0% 82%
2.5% 7.0%
0.76 V2 +15 0.40
V3 - 15 0.40
DC-DC 40W Singles
HD1-40-5A
HD1-40-5B
HD1-40-5D
9.0 12 25
18 24 36
36 48 75
4.20 V1 5.0
2.03 V1 5.0
1.00 V1 5.0
8.00
8.00
8.00
1.0% 0.3% 79%
1.0% 0.3% 82%
1.0% 0.3% 83%
Temperature Coefficient ............... 0.02%/°C over the entire operating
temperature range.
Relative Humidity .........................0 to 95%, non-condensing.
Altitude .........................................0 to 10,000 feet.
Cooling .........................................Convection cooling is adequate.
Moving air is recommended for opera-
tion in a confined area. See Package
Power De-Rating graph.
HD1-40-12A 9.0 12 25
HD1-40-12B 18 24 36
HD1-40-12D 36 48 75
4.12 V1 12
2.01 V1 12
1.00 V1 12
3.33
3.33
3.33
1.0% 0.3% 81%
1.0% 0.3% 83%
1.0% 0.3% 83%
HD1-40-15A 9.0 12 25
HD1-40-15B 18 24 36
HD1-40-15D 36 48 75
4.02 V1 15
2.01 V1 15
0.97 V1 15
2.67
2.67
2.67
1.0% 0.3% 83%
1.0% 0.3% 83%
1.0% 0.3% 86%
Storage Temperature....................-40°C to +100°C.
† HD3-30 models with tightly regulated auxiliary outputs are available. For more
information, contact Power General applications engineering.
Storage Humidity..........................0 to 95%, non-condensing.
Mean Time Between Failures.......>700,000 hours. (See Note 4.)
POWER
152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email power@nidecpg.com · http://www.nidec.com
GENERAL
47