HC5517
®
Data Sheet
October 2000
File Number 4147.3
3 REN Ringing SLIC For ISDN Modem/TA
and WLL
Features
• Thru-SLIC Open Circuit Ringing Voltage up to
77V /54V , 3 REN Capability at 44V
RMS
The HC5517 is a ringing SLIC designed to accommodate a
wide variety of local loop applications. The various applications
include, basic POTS lines with answering machines and fax
capabilities, ISDN networks, wireless local loop, and hybrid
fiber coax (HFC) terminals. The HC5517 provides a high
degree of flexibility with open circuit tip to ring DC voltages, user
defined ringing waveforms (sinusoidal to square wave), ring trip
detection thresholds and loop current limits that can be tailored
for many applications. Additional features of the HC5517 are
complex impedance matching, pulse metering and transhybrid
balance. The HC5517 is designed for use in systems where a
separate ring generator is not economically feasible.
PEAK
RMS
• Sinusoidal Ringing Capability
• DI Process Provides Substrate Latch Up Immunity when
Driving Inductive Ringers
• Adjustable On-Hook Voltage for Fax and Answering
Machine Compatibility
• Resistive and Complex Impedance Matching
• Programmable Loop Current Limit
• Switch Hook and Adjustable Ring Trip Detection
• Pulse Metering Capability
The device is manufactured in a high voltage Dielectric Isolation
(DI) process with an operating voltage range from -16V, for off-
hook operation and -80V for ring signal injection. The DI
process provides substrate latch up immunity, resulting in a
robust system design. Together with a secondary protection
diode bridge and “feed” resistors, the device will withstand
1000V lightning induced surges, in a plastic package.
• Single Low Voltage Positive Supply (+5V)
Applications
• Solid State Line Interface Circuit for Wireless Local Loop,
Hybrid Fiber Coax, Set Top Box, Voice/Data Modems
• Related Literature
- AN9606, Operation of the HC5517 Evaluation Board
- AN9607, Impedance Matching Design Equations
- AN9628, AC Voltage Gain
A thermal shutdown with an alarm output and line fault
protection are also included for operation in harsh
environments.
- AN9608, Implementing Pulse Metering
Part Number Information
- AN9636, Implementing an Analog Port for ISDN Using
the HC5517
TEMP.RANGE
o
PART NUMBER
HC5517IM
( C)
PACKAGE
28 Ld PLCC
28 Ld PLCC
28 SOIC
PKG. NO.
N28.45
N28.45
M28.3
- AN549, The HC-5502S/4X Telephone Subscriber Line
Interface Circuits (SLIC)
-40 to 85
0 to 75
HC5517CM
HC5517IB
-40 to 85
0 to 75
HC5517CB
28 SOIC
M28.3
Block Diagram
V
V
RX
TX
TIP FEED
4-WIRE
INTERFACE
TIP SENSE
2-WIRE
INTERFACE
V
RING
LOOP CURRENT
DETECTOR
RING FEED
- IN 1
-
RING SENSE 1
RING SENSE 2
+
FAULT
DETECTOR
OUT 1
V
CURRENT
LIMIT
REF
SHD
ALM
RTI
I
RING TRIP
DETECTOR
LMT
V
BAT
V
CC
BIAS
RTD
RDO
AGND
BGND
RELAY
DRIVER
IIL LOGIC INTERFACE
F1
F0
RS TST
RDI
CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.
1-888-INTERSIL or 321-724-7143 | Intersil (and design) is a registered trademark of Intersil Americas Inc.
Copyright © Intersil Americas Inc. 2002. All Rights Reserved
1