HAS30 DC-DC Series Data Sheet
Features
• Industry standard half-brick
• Low-cost design
• 100°C baseplate operation
• Open-frame packaging
• 24V and 48V input versions
• Input Pi filter
• Optional enable logic
• 1500V isolation
Description
HAS dc-dc converters provide up to 30 watts of output power in an industry-standard package and footprint. With a
maximum case temperature of 100°C, the HAS is well suited for the most demanding telecom, networking, and
industrial applications. The HAS features 1500 VDC isolation, short circuit, and overtemperature protection, as well
as six-sided shielding. The HAS series is available with optional enable and voltage trim pins. Please see the HAD
Series for dual-output applications.
Efficiency vs. Load (24V Input)
Technical Specifications
Input
90
Voltage Range
85
24 VDC Nominal
48 VDC Nominal
Transient
18 - 36 VDC
36 - 75 VDC
100V/100ms
50 mA
80
75
70
65
60
HAS030YG-A
EFF. (18v)
Reflected Ripple
EFF. (24v)
EFF. (36v)
Output
Setpoint Accuracy
1ꢀ
Line Regulation V Min. - V Max., I
Rated
0.2ꢀ V
10
20
30
40
50
60
70
80
90
100
in
in
Min. - I
out
Max., V Nom.
out
Load Regulation I
0.2ꢀ V
out
LOAD %
out
out
in
Remote Sense Headroom
Minimum Output Current
0.5 VDC
10 ꢀ
Efficiency vs. Load (48V Input)
Dynamic Regulation, Loadstep
Pk Deviation
Settling Time
25ꢀ I
out
4ꢀ V
out
95
90
85
80
75
70
65
60
55
50
500 µs
10ꢀ
Voltage Trim Range
Short Circuit / Overcurrent Protection
Current Limit Threshold Range, ꢀ of I
OVP Trip Range
Remote Shutdown Reference
Shutdown Pin Current, Sourced At Off
Hiccup
Rated
110 - 140ꢀ
out
115 - 140ꢀ V
Nom.
V Negative
in
out
HAS030ZH-A
HAS030ZG-A
HAS030ZJ-A
10 mA Max.
General
10
20
30
40
50
60
70
80
90
100
LOAD %
Turn-On Time
10 ms
Positive/Negative Logic
250 kHz
Remote Shutdown
Switching Frequency
Isolation
Notes
MTBF predictions may vary slightly from model to model.
†
Input - Output
1500 VDC
1050 VDC
500 VDC
0.03ꢀ/°C
Input - Case
Specifications typically at 25°C, normal line, and full load, unless
otherwise stated.
Output - Case
Temperature Coefficient
Case Temperature
Operating Range
Storage Range
Soldering Conditions: I/O pins, 260°C, ten seconds; fully
compatible with commercial wave-soldering equipment.
-40 To +100°C
-40 To +125°C
95ꢀ
Humidity Max., Non-Condensing
Vibration, 3 Axes, 5 Min Each
Safety: Agency approvals may vary from model to model. Please
consult factory for specific model information.
5 g, 10 - 55 Hz
6
†
MTBF (Bellcore TR-NWT-000332)
2.5 X 10 hrs
Units are water-washable and fully compatible with commercial spray or
immersion post wave-solder washing equipment.
Safety
Weight (Approx.)
UL, cUL, TUV
1.4 oz
REV. JUN 03, 2004
Page 1 of 3