PFE-SA,PFE500-F&PFE1000-FA
300-1008W AC-DC Power Module
Features
Low profile, small size
100°C baseplate temperature
High power density
High Efficiency
Suitable for conduction cooling
Power Factor Corrected (PFC)
Key Market Segments & Applications
Specifications
PFE300SA
PFE500SA
PFE700SA
PFE500F
PFE1000F*
PFE1000FA
Model
AC Input
Input Current (115 / 230VAC)
Model dependant
Inrush Current (115 / 230VAC) (1)
Power Factor
VAC
85 to 265VAC, 47-63Hz (up to 440Hz) (4)
6.8 / 3.4
3.2 / 1.6
5.2 / 2.5
13.6 / 6.6 (100/200VAC)
10.6 / 5.2
A
A
-
7.0 / 3.4
100/200VAC
23 / 46A peak
0.95 minimum, meets EN61000-3-2
Output Voltage Setpoint Accuracy
-
-
±2%
1%
±1V
4V
±2%
1%
±2%
1%
Ripple and Noise
(1)
Over Current Protection
%
105 - 140% (Automatic Recovery)
105 - 140%
Manual reset
125 - 145%
Over Voltage Protection
Series Operation
Parallel Operation
Power On Signal (ENA)
Auxiliary Supply
Remote On/Off (Opto isolated)
Overtemperature Protection
Operating Baseplate Temp.
Storage Temperature
Humidity (non condensing)
Cooling
-
-
-
-
-
-
-
°C
°C
-
125 - 145%
No
60 - 69.6V
Yes
Yes (Droop mode)
125 - 145%
Yes (Single wire)
Yes (Single wire)
Open collector (10mA sink current). Low (on) when output is present
None
None
None
None
10 - 14V, 20mA
High = On
10 - 14V, 20mA
High = On
Yes
-40 to +100°C (2)
-40 to +100°C
Operating: 20 - 95%RH, Non Operating: 10 - 95%RH
Conduction
-
Withstand Voltage (1 min)
Isolation Resistance
Vibration (non operating)
Shock
(3)
-
-
-
-
Input to Output 3kVAC, Input to Baseplate 2.5kVAC, Output to Baseplate 1.5kVDC
Output to baseplate: 100M Ohm at 500VDC, 25°C ambient, 70%RH
10-55Hz (1 min sweep), constant amplitude 0.825mm (max 49m/s2), X, Y, Z 1 hour each
196.1m/s2
Safety Certifications
-
UL60950-1, CSA60950-1 (cUL), EN60950-1, CE mark (LVD)
500
Weight
Size (WxHxL)
g
mm
in
200
250
300
420
61 x 12.7 x 116.8mm
70 x 12.7 x 122mm 100 x 13.4 x 160mm
2.4 x 0.5 x 4.6”
5 years
2.76 x 0.5 x 4.8”
2 years
3.94 x 0.53 x 6.3”
2 years
Warranty
yrs
5 years
Notes: (Consult Installation Manual for detailed specifications, test methods and application notes)
* PFE1000-F models - Last time buy March 1, 2017, please use PFE1000FA models as a replacement
1)
2)
External components are required, consult Application Notes
PFE500SA-12, PFE500F-12: -40 to 85°C. See instruction manuals for derating curves
PFE1000F28, PFE1000FA, PFE1000F48 & PFE1000FA48: -40 to 85°C below 170VAC input voltage.
See instruction manuals for derating curves
3)
4)
PFE500F, PFE1000F, PFE1000FA: 500VDC Output to baseplate
Reduced PFC above 63Hz. Contact technical support for 440Hz operation.
1-800-526-2324 • www.us.tdk-lambda.com/lp/