APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 ℃ to 105 ℃(NOTE1)
-40 ℃ to 105 ℃
CURRENT
VOLTAGE
50 V DC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
General Examination
Visually and by measuring instrument.
Confirmed visually.
×
×
×
×
According to drawing.
Marking
ELECTRIC CHARACTERISTICS
Contact Resistance
Contact Resistance
Millivolt Level Method
Insulation Resistance
1A DC.
50mΩ max.
×
×
-
-
20 mV AC max, 0.1 mA (DC or 1000Hz).
Ω
50m max.
100M min.
Ω
500 V DC.
×
×
-
-
Voltage Proof
500 V AC for 1 min.
No flashover or breakdown.
MECHANICAL CHARACTERISTICS
Mechanical Operation
30 times insertions and extractions.
① Contact resistance: 100mΩ max.
×
×
-
-
② No damage, crack and looseness of parts.
Vibration
Frequency 20 to 200 Hz,
43.1 m/s2 at 3 h for 3 directions.
① No electrical discontinuity of 10s.
② Contact resistance: 100mΩ max.
③ No damage, crack and looseness of parts.
×
×
×
-
-
-
Shock
Frequency 20 to 50 Hz,
66.6 m/s2 at 1 h.
① No electrical discontinuity of 10s.
② Contact resistance: 100mΩ max.
③ No damage, crack and looseness of parts.
×
×
×
-
-
-
Lock Strength
Applying a pull force the mating axially at 100N
max.
① During applying, mating completely.
-
-
-
-
② After applying, no defect of mating parts.
ENVIRONMENTAL CHARACTERISTICS
Damp Heat
(Steady State)
Exposed at 60℃, 90 ~ 95 %, 500 h.
① Contact resistance: 100mΩ max.
② Insulation resistance:100MΩ min.
③ No damage, crack and looseness of parts.
×
×
×
-
-
-
Rapid Change Of
Temperature
Temperature -40 → 5 to 35 → 85→ 5 to 35℃
① Contact resistance: 100mΩ max.
② Insulation resistance:100MΩ min.
③ No damage, crack and looseness of parts.
×
×
×
-
-
Time
30 →
5
→ 30 → 5 min
under 1000 cycles.
Dry Heat
℃
Exposed at 105 , 300 h.
① Contact resistance: 100mΩ max.
×
×
-
-
② No damage, crack and looseness of parts.
Cold
℃
Exposed at -40 , 120 h.
① Contact resistance: 100mΩ max.
×
×
-
-
② No damage, crack and looseness of parts.
Resistance To So2 Gas
Exposed in 25 ppm for 96 h.
Ω
Contact resistance: 100m max.
×
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(Note1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KI.HIROKAWA
MO.OKADA
20191101
20191101
20191101
20191101
Include the temperature rising by current.
(Note2)
Contact resistance of outer conductor after environmental and
durability test shall be 150mΩ max.
NK.IKUTA
DS.HIROWATARI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-373850-00-00
GT43-2428/1.6-2.9SCF
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL753-1003-0-00
FORM HD0011-2-1