APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 C TO 105 C (NOTE1)
-40 C TO 105 C
2
△
2
△
CURRENT
VOLTAGE
50 V DC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
CONFIRMED VISUALLY.
×
×
×
×
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
1A DC.
50 mΩ MAX .
50 mΩ MAX .
-
-
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
500 V DC
100 MΩ MIN.
×
×
-
-
VOLTAGE PROOF
500 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 100 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
VIBRATION
FREQUENCY 20 TO 200 Hz,
43.1 m/s2 AT 3 h FOR
DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 100 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
-
×
-
-
-
3
SHOCK
FREQUENCY 20 TO 50 Hz,
66.6 m/s2 AT 1 h .
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 100 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
-
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 100N MAX.
① DURING APPLYING,MATING COMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING
PARTS.
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
EXPOSED AT 60 C, 90 ~ 95 %, 500 h.
① CONTACT RESISTANCE: 100 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
×
-
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE-40→5 TO 35→105→5 TO 35C ① CONTACT RESISTANCE: 100 m MAX.
-
×
×
-
-
-
2
△
TIME
30 →
5
→ 30 → 5 min
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
UNDER 1000 CYCLES.
DRY HEAT
COLD
EXPOSED AT 105C, 300 h.
① CONTACT RESISTANCE: 100 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
2
△
EXPOSED AT -40C , 120 h.
① CONTACT RESISTANCE: 100 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
RESISTANCE TO SO2 GAS EXPOSED IN 25 PPM FOR 96h.
① CONTACT RESISTANCE: 100 m MAX.
② NO HARMFUL CORROSION.
-
-
-
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
NK.IKUTA
CHECKED
DATE
2
4
DIS-T-00003792
MO.OKADA
20180927
20180307
20180307
20180307
20180307
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KI.HIROKAWA
KI.HIROKAWA
KT.OKABE
INCLUDE THE TEMPERATURE RISING BY CURRENT.
CONTACT RESISTANCE OF OUTER CONDUCTOR AFTER ENVIRONMENTAL AND
(NOTE2)
DURABILITY TEST SHALL BE 150mΩ MAX.
GYEONGMIN LEE
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-376894-00-00
GT43-1S-HU(F)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
2
△
1/1
CL753-1012-0-00
FORM HD0011-2-1