APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 C TO 105 C (NOTE1)
-40 C TO 105 C
CURRENT
VOLTAGE
30 V AC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
VOLTAGE PROOF
1A DC.
30 mΩ MAX .
30 mΩ MAX .
×
×
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
100 MΩ MIN.
-
-
-
-
- V DC
NO FLASHOVER OR BREAKDOWN.
- V AC FOR 1 min.
MECHANICAL CHARACTERISTICS
INSERTION FORCE
EXTRACTION FORCE ― N .
① CONTACT RESISTANCE:60 mΩ MAX .
― N MAX.
CONTACT INSERTION AND
-
-
-
-
― BY STEEL GAUGE.
EXTRACTION FORCES
MECHANICAL OPERATION 30 TIMES INSERTIONS AND EXTRACTIONS.
×
×
-
-
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 mΩ MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
VIBRATION
SHOCK
FREQUENCY 20 TO 200 Hz,
×
×
×
-
-
-
43.1 m/s2 AT 3 h FOR 3 DIRECTIONS.
ACCELERATION 981m/s2 ,6ms AT 3 TIMES
FOR 3 DIRECTIONS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 mΩ MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
×
×
×
-
-
-
① DURING APPLYING,MATING COMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING PARTS.
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
-
-
-
-
AXIALLY AT ― N MAX.
ENVIRONMENTAL CHARACTERISTICS
① CONTACT RESISTANCE:60 mΩ MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
DAMP HEAT
×
-
×
-
-
-
EXPOSED AT 60 C, 90 ~ 95 %, 500 h.
(STEADY STATE)
① CONTACT RESISTANCE:60 mΩ MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
×
-
×
-
-
-
TEMPERATURE-40→5 TO 35→ 85→5 TO 35C
TIME 30 → → 30 → 5 min
UNDER 1000 CYCLES.
5
① CONTACT RESISTANCE:60 mΩ MAX .
DRY HEAT
COLD
EXPOSED AT 105C, 1000 h.
EXPOSED AT -40C, 1000 h.
×
×
-
-
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:60 mΩ MAX .
×
×
-
-
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:60 mΩ MAX .
RESISTANCE TO SO2 GAS EXPOSED IN 500 PPM FOR 8 h.
×
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NH.NAKATA
15.06.18
15.06.18
15.06.18
15.06.18
INCLUDE THE TEMPERATURE RISING BY CURRENT.
KI.HIROKAWA
KK.FURUKAWA
KK.FURUKAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-359508-00-00
GT32A-2428PCF
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL782-0050-7-00
FORM HD0011-2-1