APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-30 C TO +105 C (NOTE1)
-40 C TO +105 C
CURRENT
VOLTAGE
250 V AC
3
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
ACCORDING TO DRAWING.
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
×
×
×
×
MARKING
ELECTRIC CHARACTERISTICS
30 mΩ MAX .
30 mΩ MAX .
CONTACT RESISTANCE
1A DC.
-
-
-
-
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
20 mV AC MAX, 0.1 mA(OR 1kHz)
500 V DC
100 MΩ MIN.
×
×
-
-
VOLTAGE PROOF
650 V AC FOR 1 MIN.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 60 m MAX..
②
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
-
×
-
-
FREQUENCY 20 TO 200 Hz, 43.1m/s2,
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 m MAX
③
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
VIBRATION
-
-
×
-
-
-
AT 3h FOR 3 DIRECTIONS.
FREQUENCY 20 TO 50 Hz,66.6m/ s2 AT 1 h.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 m MAX
③
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
SHOCK
-
-
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 98N MAX.
① DURING APPLYING,MATING OMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING PARTS.
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
EXPOSED AT 60℃, 90 TO 95%, 500h.
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
-
×
×
-
-
-
(STEADY STATE)
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE:-40→5 TO 35→85→5 TO 35℃
TIME: 30→5→30→5 MIN
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
-
×
×
-
-
-
UNDER 1000 CYCLES.
DRY HEAT
COLD
EXPOSED AT 105℃, 300h.
EXPOSED AT -55℃, 120h.
① CONTACT RESISTANCE: 60 m MAX.
②
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
-
×
-
-
① CONTACT RESISTANCE: 60 m MAX.
②
NO DAMAGE, CRACK AND LOOSENESS, OF PARTS.
-
×
-
-
RESISTANCE TO SO2 GAS
RESISTANCE TO WATER
EXPOSED IN 500 PPM FOR 8h.
① CONTACT RESISTANCE: 60 m MAX.
NO WATER PENETRATION PERMITTED.
-
×
-
-
①EXPOSED TO 80℃ ENVIROMENT FOR 1h,
②IMMERSED IN THE WATER TO THE DEPTH
100mm FOR 0.5h, ③LEFT IN THE AMBIENT
TEMPERATURE FOR 2h, STEPS ② AND ③ ARE
1 CYCLE, 10CYCLES PERFORMED.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NH.NAKATA
15.10.22
15.10.21
15.10.20
15.10.20
INCLUDE THE TEMPERATURE RISING BY CURRENT.
KI.HIROKAWA
KK.FURUKAWA
KK.FURUKAWA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-167295-00-00
GT17W-1P/S-R
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL767-0216-5-00
FORM HD0011-2-1