APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-40 C TO 105 C (NOTE1)
-40 C TO 105 C
CURRENT
VOLTAGE
250 V AC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
MARKING
VISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
CONFIRMED VISUALLY.
×
×
×
×
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
1A DC.
SIGNAL:30 mΩ MAX,SHIELD:60 mΩ MAX .
SIGNAL : 30 mΩ MAX,SHIELD:60 mΩ MAX .
×
×
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
INSULATION RESISTANCE 500 V DC
100 MΩ MIN.
NO FLASHOVER OR BREAKDOWN.
×
×
-
-
VOLTAGE PROOF
650 V AC FOR 1 min.
MECHANICAL CHARACTERISTICS
MECHANICAL OPERATION 30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE:
×
×
-
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
-
-
-
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:
VIBRATION
SHOCK
FREQUENCY 20 TO 200 Hz,
43.1 m/s2 AT 3 h FOR
DIRECTIONS.
×
×
3
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:
×
×
×
-
-
-
FREQUENCY 20 TO 50 Hz,
66.6 m/s2 AT 1 h .
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① DURING APPLYING,MATING COMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING PARTS.
×
×
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 98N MAX.
ENVIRONMENTAL CHARACTERISTICS
① CONTACT RESISTANCE:
DAMP HEAT
×
-
EXPOSED AT 60 C, 90 ~ 95 %, 500 h.
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:
(STEADY STATE)
×
×
×
-
-
-
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE-40→5 TO 35→ 85→5 TO 35C
TIME 30 → → 30 → 5 min
UNDER 1000 CYCLES.
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:
5
×
×
×
-
-
-
DRY HEAT
COLD
EXPOSED AT 105C, 1000 h.
EXPOSED AT -40C, 1000 h.
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:
×
×
-
-
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
① CONTACT RESISTANCE:
×
×
-
-
RESISTANCE TO SO2 GAS EXPOSED IN 500 PPM FOR 8 h.
SIGNAL:60 mΩ MAX,SHIELD:120 mΩ MAX .
② NO HEAVY CORROSION.
×
×
-
-
NO DEFORMATION OF CASE OF EXCESSIVE
LOOSENESS OF THE TERMINALS.
RESISTANCE TO
SOLDERING HEAT
SPECIFIED TEMPERATURE PROFILE FOR
2 TIMES.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
KI.HIROKAWA
EJ.WAKATSUKI
TS.KUBOTA
20200326
20200325
20200325
20200221
INCLUDE THE TEMPERATURE RISING BY CURRENT.
(NOTE2)
APPLICABLE BOARD : 1.6±0.2
YK.MITSUISHI
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-168892-56-00
GT17HN2-4DP-2H(A)(56)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
CL767-0267-6-56
△
1/1
FORM HD0011-2-1