APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-30 C TO 105 C (NOTE1)
-40 C TO 105 C
CURRENT
VOLTAGE
250 V AC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
VISUALLY AND BY MEASURING INSTRUMENT. ACCORDING TO DRAWING.
CONFIRMED VISUALLY.
×
×
×
×
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
INSULATION RESISTANCE
1A DC.
30 mΩ MAX .
30 mΩ MAX .
-
-
-
-
20 mV AC MAX, 0.1 mA(DC OR 1000Hz)
500 V DC
100 MΩ MIN.
×
×
-
-
VOLTAGE PROOF
650 V AC FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION AND
EXTRACTION FORCES
BY STEEL GAUGE, -.
INSERTION FORCE
- N MAX.
-
-
-
-
EXTRACTION FORCE - N MIN.
MECHANICAL OPERATION
VIBRATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
FREQUENCY 20 TO 200 Hz,
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 60 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
-
×
-
-
-
43.1 m/s2 AT 3 h FOR
3
DIRECTIONS.
SHOCK
FREQUENCY 20 TO 50 Hz,
66.6 m/s2 AT 1 h .
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE: 60 m MAX.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
-
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 98N MAX.
① DURING APPLYING,MATING COMPLETELY.
② AFTER APPLYING,NO DEFECT OF MATING
PARTS.
×
×
-
-
ENVIRONMENTAL CHARACTERISTICS
DAMP HEAT
(STEADY STATE)
EXPOSED AT 60 C, 90 TO 95 %, 500 h.
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
-
×
×
-
-
-
PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE-40→5 TO 35→ 85→5 TO 35C ① CONTACT RESISTANCE: 60 m MAX.
-
×
×
-
-
-
TIME
30 →
5
→ 30 → 5 min
② INSULATION RESISTANCE:100 M MIN.
③ NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
UNDER 1000 CYCLES.
DRY HEAT
COLD
EXPOSED AT 105C, 300 h.
EXPOSED AT -55C , 120 h.
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
① CONTACT RESISTANCE: 60 m MAX.
② NO DAMAGE, CRACK AND LOOSENESS OF
PARTS.
-
×
-
-
RESISTANCE TO SO2 GAS EXPOSED IN 500 ppm FOR 8h.
① CONTACT RESISTANCE: 60 m MAX.
-
-
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
(NOTE1)
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NH.NAKATA
15.09.03
15.09.03
15.08.24
15.08.24
INCLUDE THE TEMPERATURE RISING BY CURRENT.
KI.HIROKAWA
ming.jiang
ming.jiang
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-166311-00-00
GT16C-1PP-HU(B)
SPECIFICATION SHEET
HIROSE ELECTRIC CO., LTD.
0
△
1/1
CL766-0065-5-00
FORM HD0011-2-1