APPLICABLE STANDARD
OPERATING
TEMPERATURE RANGE
RATING
STORAGE
TEMPERATURE RANGE
-30 C TO 105 C (NOTE1)
-40 C TO 105 C
CURRENT
VOLTAGE
250 V AC
1
A
SPECIFICATIONS
ITEM
TEST METHOD
REQUIREMENTS
QT AT
CONSTRUCTION
GENERAL EXAMINATION
ACCORDING TO DRAWING.
VISUALLY AND BY MEASURING INSTRUMENT.
CONFIRMED VISUALLY.
×
×
×
×
MARKING
ELECTRIC CHARACTERISTICS
CONTACT RESISTANCE
1A DC.
30 mΩ MAX .
30 mΩ MAX .
×
×
-
-
CONTACT RESISTANCE
MILLIVOLT LEVEL METHOD
20 mV AC MAX, 0.1 mA(OR 1kHz)
INSULATION RESISTANCE
VOLTAGE PROOF
DC 500 V
100 MΩ MIN.
×
×
-
-
AC 650 V FOR 1 min.
NO FLASHOVER OR BREAKDOWN.
MECHANICAL CHARACTERISTICS
CONTACT INSERTION
BY STEEL GAUGE.
INSERTION FORCE
EXTRACTION FORCE
N MAX.
N MIN.
AND EXTRACTION FORCES
-
×
×
-
-
-
MECHANICAL OPERATION
VIBRATION
30 TIMES INSERTIONS AND EXTRACTIONS.
① CONTACT RESISTANCE: 60 m MAX..
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
FREQUENCY 20 TO 200 Hz, 43.1m/s2,
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 m MAX
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
AT 3h FOR 3 DIRECTIONS.
FREQUENCY 20 TO 50 Hz, 66.6m/ s2 AT 1 h.
SHOCK
① NO ELECTRICAL DISCONTINUITY OF 10 s.
② CONTACT RESISTANCE:60 m MAX
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
×
-
-
-
LOCK STRENGTH
APPLYING A PULL FORCE THE MATING
AXIALLY AT 98N MAX.
① DURING APPLYING,MATING OMPLETELY.
② AFTER APPLYING,NO DEFECT OF
MATING PARTS.
ENVIRONMENTAL CHARACTERISTICS
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
DAMP HEAT
EXPOSED AT 60℃, 90 TO 95%, 500h.
(STEADY STATE)
×
-
① CONTACT RESISTANCE: 60 m MAX.
② INSULATION RESISTANCE:100 M MIN.
③
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
RAPID CHANGE OF
TEMPERATURE
TEMPERATURE:-40→5 TO 35→85→5 TO 35℃
TIME: 30→5→30→5 MIN
UNDER 1000 CYCLES.
×
×
-
-
① CONTACT RESISTANCE: 60 m MAX.
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
DRY HEAT
EXPOSED AT 105℃, 300h.
① CONTACT RESISTANCE: 60 m MAX.
②
NO DAMAGE, CRACK AND LOOSENESS OF PARTS.
COLD
EXPOSED AT -55℃, 120h.
×
×
-
-
① CONTACT RESISTANCE: 60 m MAX.
② NO HEAVY CORROSION.
RESISTANCE TO HSO3 GAS
EXPOSED IN 500 PPM FOR 8h.
COUNT
DESCRIPTION OF REVISIONS
DESIGNED
CHECKED
DATE
0
△
REMARK
APPROVED
CHECKED
DESIGNED
DRAWN
NH.NAKATA
15.08.08
15.08.07
15.08.06
15.08.06
(NOTE1)
INCLUDE THE TEMPERATURE RISING BY CURRENT.
KI.HIROKAWA
NK.IKUTA
NK.IKUTA
Note QT:Qualification Test AT:Assurance Test X:Applicable Test
DRAWING NO.
PART NO.
CODE NO.
ELC-165919-00-00
GT16-30PCF
SPECIFICATION SHEET
0
△
1/1
HIROSE ELECTRIC CO., LTD.
CL766-0015-7-00