20~25W AC-DC Single Output Wall-mounted type
GS25E series
Features :
Universal AC input / Full range
No load power consumption<0.5W
Pass energy star(CEC) level regulation
Meet EISA 2007 (Energy Independence and Security Act)
2 pole EURO plug
Class power (without earth pin)
Full output 5~48V safety approval
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Approvals: TUV / CB / CE
Pass LPS for 9~48V output
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
SPECIFICATION
ORDER NO.
GS25E05-P1J GS25E07-P1J GS25E09-P1J GS25E12-P1J GS25E15-P1J GS25E18-P1J GS25E24-P1J GS25E28-P1J GS25E48-P1J
SAFETY MODEL NO.
GS25E05
Note.2 5V
GS25E07
7.5V
GS25E09
9V
GS25E12
12V
GS25E15
15V
GS25E18
18V
GS25E24
24V
GS25E28
28V
GS25E48
48V
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
4.0A
2.93A
2.77A
0 ~ 2.77A
25W
2.08A
0 ~ 2.08A
25W
1.66A
1.38A
1.04A
0.89A
0.52A
0 ~ 4.0A
20W
0 ~ 2.93A
22W
0 ~ 1.66A
25W
0 ~ 1.38A
25W
0 ~ 1.04A
25W
0 ~ 0.89A
25W
0 ~ 0.52A
25W
OUTPUT
RIPPLE & NOISE (max.) Note.3 50mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
80mVp-p
5.0%
80mVp-p
5.0%
80mVp-p
3.0%
100mVp-p
3.0%
150mVp-p
3.0%
180mVp-p
2.0%
240mVp-p
2.0%
240mVp-p
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
3.0%
3.0%
3.0%
2.0%
2.0%
2.0%
SETUP, RISE, HOLD UP TIME 500ms, 20ms, 50ms/230VAC
500ms, 20ms, 15ms/115VAC at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
74%
78%
79%
81%
82%
82%
83%
83%
84%
INPUT
AC CURRENT
0.7A / 100VAC
45A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
110 ~ 150% rated output power
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Clamp by zener diode
0 ~ +50 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
TUV EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
I/P-O/P:4242VDC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMC
(Note. 7)
Compliance to EN61000-3-2,3
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
79*54*33mm (L*W*H)
)
DIMENSION
OTHERS
210g ; 60pcs / 13.5kg / CARTON
PACKING
PLUG
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
Standard type UL1185 6ft (4FT only for 5V output) for stock ; Other type available by customer requested
CONNECTOR
CABLE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 20% to 100% rated load
7.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS25E-SPEC 2008-05-08