4 ~ 6W AC-DC Single Output Wall-mounted type
GS06E series
Features :
Universal AC input / Full range
No load power consumption <0.5W
Meet energy star level IV(CEC) for 5 ~ 48V
Meet EISA 2007 (Energy Independence and Security Act) for 5 ~ 48V
2 pole EURO plug
Class power (without earth pin)
Full output 3~48V safety approval
Protections: Short circuit / Overload / Over voltage
Pass LPS
Fully enclosed plastic case
Approvals: TUV / CB / FCC / CE
2 years warranty
TUV
geprUfre
Rheinland
Sicherheit
Product Safety
SPECIFICATION
ORDER NO.
GS06E-0P1J GS06E-1P1J GS06E-11P1J GS06E-2P1J GS06E-3P1J GS06E-4P1J GS06E-5P1J GS06E-6P1J GS06E-8P1J
SAFETY MODEL NO.
GPSU06-0-E GPSU06-1-E GPSU06-1-1-E GPSU06-2-E GPSU06-3-E GPSU06-4-E GPSU06-5-E GPSU06-6-E GPSU06-8-E
DC VOLTAGE
Note.2 3.3V
5V
7.5V
9V
12V
15V
18V
24V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
1.21A
1.00A
0 ~ 1.00A
5W
0.8A
0.66A
0 ~ 0.66A
6W
0.5A
0.4A
0.33A
0.25A
0.125A
0 ~ 0.125A
6W
0 ~ 1.21A
4W
0 ~ 0.8A
6W
0 ~ 0.5A
6W
0 ~ 0.4A
6W
0 ~ 0.33A
6W
0 ~ 0.25A
6W
RIPPLE & NOISE (max.) Note.3 50mVp-p
50mVp-p
5 ~ 6V
80mVp-p
6 ~ 8V
80mVp-p
8 ~ 11V
100mVp-p
11 ~ 13V
120mVp-p
13 ~ 16V
150mVp-p
16 ~ 21V
180mVp-p
21 ~ 27V
200mVp-p
33 ~ 48V
OUTPUT
3 ~ 5V
VOLTAGE ADJ. RANGE
Fixed
VOLTAGE TOLERANCE Note.4 5.0%
5.0%
0.5%
5.0%
5.0%
0.5%
5.0%
5.0%
0.5%
5.0%
3.0%
0.5%
3.0%
3.0%
0.5%
3.0%
3.0%
0.5%
3.0%
2.0%
0.5%
2.0%
2.0%
0.5%
2.0%
LINE REGULATION
LOAD REGULATION
Note.5 1.0%
Note.6 5.0%
SETUP, RISE, HOLD UP TIME 1000ms, 50ms, 12ms at full load
VOLTAGE RANGE
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
Note.7 55%
67%
72%
74%
76%
77%
78%
80%
82%
INPUT
AC CURRENT
0.2A / 100VAC
50A / 230VAC
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
0.25mA / 240VAC
>105% rated output voltage power for 3.3 ~ 5V ; >110% rated output power for 7.5 ~ 48V
OVERLOAD
Protection type : Hiccup mode, recovers automatically after fault condition is removed
>120% rated output power
PROTECTION
ENVIRONMENT
OVER VOLTAGE
Protection type : Clamp by zener diode
0 ~ +40 (Refer to output load derating curve)
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-20 ~ +85 , 10 ~ 95% RH
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
EN60950-1 approved
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
I/P-O/P:4242VDC
SAFETY &
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC Part15 class B
Compliance to EN61000-3-2,3
EMC
(Note. 8)
EMS IMMUNITY
MTBF
Compliance to EN61000-4-2,3,4,5,6,11, light industry level, criteria A
500Khrs min. MIL-HDBK-217F(25
32*66*42.5mm (L*W*H)
)
OTHERS
DIMENSION
100g ; 90pcs / 10Kg / CARTON
PACKING
PLUG
Standard type P1J: 2.1 * 5.5 * 11mm, turning fork type center positive for stock ; Other type available by customer requested
Standard type 20Awg UL1185 6ft for stock ; Other type available by customer requested
CONNECTOR
CABLE
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 0% to 100% rated load
7.Efficiency is measured at 230VAC.
8.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
File Name:GS06E-SPEC 2008-05-06